FabDigitFabDigit

Aluminum EN AC-71100-F vs EN AC-71100-T1

Aluminum · EN AC-71100 temper comparison

EN AC-71100-F and EN AC-71100-T1 are two conditions of the same aluminum grade, EN AC-71100: F (as fabricated) versus T1 (cooled from hot working and naturally aged). The chemistry is identical, so every difference below comes from the condition. EN AC-71100-T1 is the stronger of the two: yield strength 205 MPa (29.7 ksi) against 150 MPa (21.8 ksi) for EN AC-71100-F, about 37% more; tensile strength follows at 270 MPa (39.2 ksi) vs 230 MPa (33.4 ksi). In exchange, EN AC-71100-F is the more ductile: elongation 2% versus 1.5% for EN AC-71100-T1, and EN AC-71100-T1 is harder (90 HB vs 70 HB).

EN AC-71100-FChoose it when the part is bent, formed or impact-loaded.

EN AC-71100-T1Choose it when strength drives the design.

EN AC-71100-F vs EN AC-71100-T1: properties

EN AC-71100-FEN AC-71100-T1

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

230 MPa33.4 ksi
270 MPa39.2 ksi

Yield Strength (0.2% offset)

150 MPa21.8 ksi
205 MPa29.7 ksi

Elongation at Break

2%
1.5%

Compressive Strength

160 MPa23.2 ksi
215 MPa31.2 ksi

Shear Strength

145 MPa21 ksi
170 MPa24.7 ksi

Fatigue Strength (Endurance Limit)

75 MPa10.9 ksi
85 MPa12.3 ksi

Fracture Toughness (K_IC)

17 MPa·√m15.5 ksi·√in
15 MPa·√m13.7 ksi·√in

Charpy V-Notch Impact (RT)

3 J2.2 ft·lbf
2 J1.5 ft·lbf

Hardness, Brinell

70 HB
90 HB

Hardness, Rockwell B

36 HRB
52 HRB

Hardness, Vickers

74 HV
95 HV

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.9 g/cm³0.1 lb/in³ · Melting Point (Solidus) 550°C1,022 °F · Liquidus Temperature 600°C1,112 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

115 W/m·K66.4 BTU/hr·ft·°F
110 W/m·K63.6 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 880 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 400 J/g172 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

28 % IACS
27 % IACS

Electrical Resistivity

6.2×10⁻⁸ Ω·m2.44 µΩ·in
6.4×10⁻⁸ Ω·m2.52 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

42 / 100
40 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.87 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

68 / 100
72 / 100

Machinability Rating (AISI 1212 = 100 %)

120%
130%

Weldability

22 / 100
20 / 100

Formability (cold)

7 / 100
5 / 100

Same in both: Castability 75 / 100 · Brazeability / Solderability 20 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 190 MJ/kg81,685 BTU/lb · Embodied Carbon (primary production) 11.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-71100

EN AC-71100-F vs EN AC-71100-T1 — frequently asked

Is EN AC-71100-T1 stronger than EN AC-71100-F?

Yes. EN AC-71100-T1 has a typical yield strength of 205 MPa (29.7 ksi) against 150 MPa (21.8 ksi) for EN AC-71100-F — about 37% more. Tensile strength is 270 MPa (39.2 ksi) vs 230 MPa (33.4 ksi).

Which condition does FabDigit quote by default, F or T1?

T1 is the default EN AC-71100 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose EN AC-71100-F over EN AC-71100-T1?

Pick EN AC-71100-F when the part is bent, formed or impact-loaded. Pick EN AC-71100-T1 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-71100-F and EN AC-71100-T1 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.