FabDigitFabDigit

Aluminum EN AC-48000-F vs EN AC-48000-T7

Aluminum · EN AC-48000 temper comparison

EN AC-48000-F and EN AC-48000-T7 are two conditions of the same aluminum grade, EN AC-48000: F (as fabricated) versus T7 (solution heat treated and overaged (stabilized)). The chemistry is identical, so every difference below comes from the condition. EN AC-48000-T7 is the stronger of the two: yield strength 215 MPa (31.2 ksi) against 130 MPa (18.9 ksi) for EN AC-48000-F, about 65% more; tensile strength follows at 250 MPa (36.3 ksi) vs 180 MPa (26.1 ksi). In exchange, EN AC-48000-F is the more ductile: elongation 1.5% versus 1.2% for EN AC-48000-T7, and EN AC-48000-T7 is harder (105 HB vs 85 HB). EN AC-48000-T7 runs hotter in service (280°C vs 180°C continuous).

EN AC-48000-FChoose it when the part is bent, formed or impact-loaded.

EN AC-48000-T7Choose it when strength drives the design, or when the part sees heat.

EN AC-48000-F vs EN AC-48000-T7: properties

EN AC-48000-FEN AC-48000-T7

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

180 MPa26.1 ksi
250 MPa36.3 ksi

Yield Strength (0.2% offset)

130 MPa18.9 ksi
215 MPa31.2 ksi

Elongation at Break

1.5%
1.2%

Shear Strength

145 MPa21 ksi
185 MPa26.8 ksi

Fatigue Strength (Endurance Limit)

80 MPa11.6 ksi
98 MPa14.2 ksi

Hardness, Brinell

85 HB
105 HB

Hardness, Vickers

90 HV
110 HV

Same in both: Elastic (Young's) Modulus 82 GPa11.9 Msi · Shear Modulus 31 GPa4.5 Msi · Bulk Modulus 78 GPa11.3 Msi · Poisson's Ratio 0.33 · Compressive Strength 480 MPa69.6 ksi · Fracture Toughness (K_IC) 14 MPa·√m12.7 ksi·√in · Charpy V-Notch Impact (RT) 2 J1.5 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 510°C950 °F · Liquidus Temperature 570°C1,058 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

140 W/m·K80.9 BTU/hr·ft·°F
138 W/m·K79.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

180°C356 °F
280°C536 °F

Same in both: Specific Heat Capacity 880 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 19.5 µm/m·K10.8 µin/in·°F · Latent Heat of Fusion 490 J/g211 BTU/lb · Min Service Temperature -60°C-76 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

29 % IACS
28 % IACS

Electrical Resistivity

5.9×10⁻⁸ Ω·m2.32 µΩ·in
6.2×10⁻⁸ Ω·m2.44 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.8 V · Corrosion Resistance 42 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
57 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 65% · Weldability 25 / 100 · Formability (cold) 5 / 100 · Castability 85 / 100 · Brazeability / Solderability 20 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 65%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-48000

EN AC-48000-F vs EN AC-48000-T7 — frequently asked

Is EN AC-48000-T7 stronger than EN AC-48000-F?

Yes. EN AC-48000-T7 has a typical yield strength of 215 MPa (31.2 ksi) against 130 MPa (18.9 ksi) for EN AC-48000-F — about 65% more. Tensile strength is 250 MPa (36.3 ksi) vs 180 MPa (26.1 ksi).

Which condition does FabDigit quote by default, F or T7?

T6 is the default EN AC-48000 condition in the FabDigit quote flow (neither F nor T7). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose EN AC-48000-F over EN AC-48000-T7?

Pick EN AC-48000-F when the part is bent, formed or impact-loaded. Pick EN AC-48000-T7 when strength drives the design, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-48000-F and EN AC-48000-T7 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.