FabDigitFabDigit

Aluminum EN AC-48000-T6 vs EN AC-48000-T7

Aluminum · EN AC-48000 temper comparison

EN AC-48000-T6 and EN AC-48000-T7 are two conditions of the same aluminum grade, EN AC-48000: T6 (solution heat treated and artificially aged) versus T7 (solution heat treated and overaged (stabilized)). The chemistry is identical, so every difference below comes from the condition. EN AC-48000-T6 is the stronger of the two: yield strength 255 MPa (37 ksi) against 215 MPa (31.2 ksi) for EN AC-48000-T7, about 19% more; tensile strength follows at 295 MPa (42.8 ksi) vs 250 MPa (36.3 ksi). In exchange, EN AC-48000-T7 is the more ductile: elongation 1.2% versus 1% for EN AC-48000-T6, and EN AC-48000-T6 is harder (115 HB vs 105 HB). EN AC-48000-T7 runs hotter in service (280°C vs 250°C continuous) and EN AC-48000-T6 conducts electricity better (33 % IACS vs 28 % IACS).

EN AC-48000-T6Choose it when strength drives the design.

EN AC-48000-T7Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

EN AC-48000-T6 vs EN AC-48000-T7: properties

EN AC-48000-T6EN AC-48000-T7

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

295 MPa42.8 ksi
250 MPa36.3 ksi

Yield Strength (0.2% offset)

255 MPa37 ksi
215 MPa31.2 ksi

Elongation at Break

1%
1.2%

Shear Strength

195 MPa28.3 ksi
185 MPa26.8 ksi

Fatigue Strength (Endurance Limit)

95 MPa13.8 ksi
98 MPa14.2 ksi

Hardness, Brinell

115 HB
105 HB

Hardness, Vickers

120 HV
110 HV

Same in both: Elastic (Young's) Modulus 82 GPa11.9 Msi · Shear Modulus 31 GPa4.5 Msi · Bulk Modulus 78 GPa11.3 Msi · Poisson's Ratio 0.33 · Compressive Strength 480 MPa69.6 ksi · Fracture Toughness (K_IC) 14 MPa·√m12.7 ksi·√in · Charpy V-Notch Impact (RT) 2 J1.5 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 510°C950 °F · Liquidus Temperature 570°C1,058 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

135 W/m·K78 BTU/hr·ft·°F
138 W/m·K79.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

250°C482 °F
280°C536 °F

Same in both: Specific Heat Capacity 880 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 19.5 µm/m·K10.8 µin/in·°F · Latent Heat of Fusion 490 J/g211 BTU/lb · Min Service Temperature -60°C-76 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

33 % IACS
28 % IACS

Electrical Resistivity

5.2×10⁻⁸ Ω·m2.05 µΩ·in
6.2×10⁻⁸ Ω·m2.44 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.8 V · Corrosion Resistance 42 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

48 / 100
57 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 65% · Weldability 25 / 100 · Formability (cold) 5 / 100 · Castability 85 / 100 · Brazeability / Solderability 20 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 65%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-48000

EN AC-48000-T6 vs EN AC-48000-T7 — frequently asked

Is EN AC-48000-T6 stronger than EN AC-48000-T7?

Yes. EN AC-48000-T6 has a typical yield strength of 255 MPa (37 ksi) against 215 MPa (31.2 ksi) for EN AC-48000-T7 — about 19% more. Tensile strength is 295 MPa (42.8 ksi) vs 250 MPa (36.3 ksi).

Which condition does FabDigit quote by default, T6 or T7?

T6 is the default EN AC-48000 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, EN AC-48000-T6 or EN AC-48000-T7?

EN AC-48000-T7. Its machinability rates good (57/100) against fair (48/100) for EN AC-48000-T6.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-48000-T6 and EN AC-48000-T7 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.