FabDigitFabDigit

Aluminum EN AC-43300-T5 vs EN AC-43300-T64

Aluminum · EN AC-43300 temper comparison

EN AC-43300-T5 and EN AC-43300-T64 are two conditions of the same aluminum grade, EN AC-43300: T5 (cooled from hot working and artificially aged) versus T64 (solution heat treated and under-aged). The chemistry is identical, so every difference below comes from the condition. EN AC-43300-T64 is the stronger of the two: yield strength 180 MPa (26.1 ksi) against 150 MPa (21.8 ksi) for EN AC-43300-T5, about 20% more; tensile strength follows at 250 MPa (36.3 ksi) vs 210 MPa (30.5 ksi). EN AC-43300-T64 is the more ductile: elongation 6% versus 2.5% for EN AC-43300-T5, and EN AC-43300-T64 is harder (80 HB vs 72 HB).

EN AC-43300-T64Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

EN AC-43300-T5 vs EN AC-43300-T64: properties

EN AC-43300-T5EN AC-43300-T64

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

74 GPa10.7 Msi
73 GPa10.6 Msi

Tensile Strength (Ultimate)

210 MPa30.5 ksi
250 MPa36.3 ksi

Yield Strength (0.2% offset)

150 MPa21.8 ksi
180 MPa26.1 ksi

Elongation at Break

2.5%
6%

Compressive Strength

160 MPa23.2 ksi
185 MPa26.8 ksi

Shear Strength

140 MPa20.3 ksi
165 MPa23.9 ksi

Fracture Toughness (K_IC)

25 MPa·√m22.8 ksi·√in
24 MPa·√m21.8 ksi·√in

Charpy V-Notch Impact (RT)

3 J2.2 ft·lbf
7 J5.2 ft·lbf

Hardness, Brinell

72 HB
80 HB

Hardness, Vickers

76 HV
85 HV

Same in both: Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33 · Fatigue Strength (Endurance Limit) 80 MPa11.6 ksi

Physical

Density and transition temperatures.

Same in both: Density 2.65 g/cm³0.1 lb/in³ · Melting Point (Solidus) 557°C1,035 °F · Liquidus Temperature 596°C1,105 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

155 W/m·K89.6 BTU/hr·ft·°F
158 W/m·K91.3 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21 µm/m·K11.7 µin/in·°F · Latent Heat of Fusion 425 J/g183 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

39 % IACS
42 % IACS

Electrical Resistivity

4.4×10⁻⁸ Ω·m1.73 µΩ·in
4.1×10⁻⁸ Ω·m1.61 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

58 / 100
62 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

68%
65%

Weldability

70 / 100
75 / 100

Formability (cold)

10 / 100
22 / 100

Same in both: Machinability 58 / 100 · Castability 90 / 100 · Brazeability / Solderability 35 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-43300

EN AC-43300-T5 vs EN AC-43300-T64 — frequently asked

Is EN AC-43300-T64 stronger than EN AC-43300-T5?

Yes. EN AC-43300-T64 has a typical yield strength of 180 MPa (26.1 ksi) against 150 MPa (21.8 ksi) for EN AC-43300-T5 — about 20% more. Tensile strength is 250 MPa (36.3 ksi) vs 210 MPa (30.5 ksi).

Which condition does FabDigit quote by default, T5 or T64?

T6 is the default EN AC-43300 condition in the FabDigit quote flow (neither T5 nor T64). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, EN AC-43300-T5 or EN AC-43300-T64?

EN AC-43300-T64. Its weldability rates very good (75/100) against very good (70/100) for EN AC-43300-T5.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-43300-T5 and EN AC-43300-T64 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.