EN AC-43300-F and EN AC-43300-T5 are two conditions of the same aluminum grade, EN AC-43300: F (as fabricated) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-43300-T5 is the stronger of the two: yield strength 150 MPa (21.8 ksi) against 95 MPa (13.8 ksi) for EN AC-43300-F, about 58% more; tensile strength follows at 210 MPa (30.5 ksi) vs 180 MPa (26.1 ksi). In exchange, EN AC-43300-F is the more ductile: elongation 3% versus 2.5% for EN AC-43300-T5, and EN AC-43300-T5 is harder (72 HB vs 60 HB).

EN AC-43300-FChoose it when the part is bent, formed or impact-loaded.

EN AC-43300-T5Choose it when strength drives the design.

EN AC-43300-F vs EN AC-43300-T5: properties

EN AC-43300-FEN AC-43300-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

73 GPa10.6 Msi
74 GPa10.7 Msi

Tensile Strength (Ultimate)

180 MPa26.1 ksi
210 MPa30.5 ksi

Yield Strength (0.2% offset)

95 MPa13.8 ksi
150 MPa21.8 ksi

Elongation at Break

3%
2.5%

Compressive Strength

215 MPa31.2 ksi
160 MPa23.2 ksi

Shear Strength

125 MPa18.1 ksi
140 MPa20.3 ksi

Fatigue Strength (Endurance Limit)

70 MPa10.2 ksi
80 MPa11.6 ksi

Fracture Toughness (K_IC)

20 MPa·√m18.2 ksi·√in
25 MPa·√m22.8 ksi·√in

Charpy V-Notch Impact (RT)

4 J3 ft·lbf
3 J2.2 ft·lbf

Hardness, Brinell

60 HB
72 HB

Hardness, Vickers

63 HV
76 HV

Same in both: Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.65 g/cm³0.1 lb/in³ · Melting Point (Solidus) 557°C1,035 °F · Liquidus Temperature 596°C1,105 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 155 W/m·K89.6 BTU/hr·ft·°F · Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21 µm/m·K11.7 µin/in·°F · Latent Heat of Fusion 425 J/g183 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 39 % IACS · Electrical Resistivity 4.4×10⁻⁸ Ω·m1.73 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
58 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
68%

Weldability

75 / 100
70 / 100

Formability (cold)

15 / 100
10 / 100

Same in both: Castability 90 / 100 · Brazeability / Solderability 35 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-43300

EN AC-43300-F vs EN AC-43300-T5 — frequently asked

Is EN AC-43300-T5 stronger than EN AC-43300-F?

Yes. EN AC-43300-T5 has a typical yield strength of 150 MPa (21.8 ksi) against 95 MPa (13.8 ksi) for EN AC-43300-F — about 58% more. Tensile strength is 210 MPa (30.5 ksi) vs 180 MPa (26.1 ksi).

Which condition does FabDigit quote by default, F or T5?

T6 is the default EN AC-43300 condition in the FabDigit quote flow (neither F nor T5). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, EN AC-43300-F or EN AC-43300-T5?

EN AC-43300-F. Its weldability rates very good (75/100) against very good (70/100) for EN AC-43300-T5.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-43300-F and EN AC-43300-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.