FabDigitFabDigit

Aluminum EN AC-41000-T6 vs EN AC-41000 T6-K

Aluminum · EN AC-41000 temper comparison

EN AC-41000-T6 and EN AC-41000 T6-K are two conditions of the same aluminum grade, EN AC-41000: T6 (solution heat treated and artificially aged) versus T6-K (T6). The chemistry is identical, so every difference below comes from the condition. EN AC-41000 T6-K is the stronger of the two: yield strength 195 MPa (28.3 ksi) against 130 MPa (18.9 ksi) for EN AC-41000-T6, about 50% more; tensile strength follows at 260 MPa (37.7 ksi) vs 190 MPa (27.6 ksi). EN AC-41000 T6-K is the more ductile: elongation 7% versus 5% for EN AC-41000-T6, and EN AC-41000 T6-K is harder (78 HB vs 55 HB). On the shop floor, EN AC-41000 T6-K welds better (very good vs good).

EN AC-41000 T6-KChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

EN AC-41000-T6 vs EN AC-41000 T6-K: properties

EN AC-41000-T6EN AC-41000 T6-K

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

190 MPa27.6 ksi
260 MPa37.7 ksi

Yield Strength (0.2% offset)

130 MPa18.9 ksi
195 MPa28.3 ksi

Elongation at Break

5%
7%

Shear Strength

125 MPa18.1 ksi
170 MPa24.7 ksi

Fatigue Strength (Endurance Limit)

65 MPa9.4 ksi
75 MPa10.9 ksi

Charpy V-Notch Impact (RT)

5 J3.7 ft·lbf
10 J7.4 ft·lbf

Hardness, Brinell

55 HB
78 HB

Same in both: Elastic (Young's) Modulus 72 GPa10.4 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33 · Compressive Strength 140 MPa20.3 ksi · Fracture Toughness (K_IC) 25 MPa·√m22.8 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 2.67 g/cm³0.1 lb/in³ · Melting Point (Solidus) 610°C1,130 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

170 W/m·K98.2 BTU/hr·ft·°F
172 W/m·K99.4 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.5 µm/m·K12.5 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

42 % IACS
41 % IACS

Electrical Resistivity

4.1×10⁻⁸ Ω·m1.61 µΩ·in
4.2×10⁻⁸ Ω·m1.65 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

68 / 100
72 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

68 / 100
62 / 100

Weldability

68 / 100
80 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 160% · Formability (cold) 20 / 100 · Castability 55 / 100 · Brazeability / Solderability 40 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.3 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-41000

EN AC-41000-T6 vs EN AC-41000 T6-K — frequently asked

Is EN AC-41000 T6-K stronger than EN AC-41000-T6?

Yes. EN AC-41000 T6-K has a typical yield strength of 195 MPa (28.3 ksi) against 130 MPa (18.9 ksi) for EN AC-41000-T6 — about 50% more. Tensile strength is 260 MPa (37.7 ksi) vs 190 MPa (27.6 ksi).

Which condition does FabDigit quote by default, T6 or T6-K?

T6 is the default EN AC-41000 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, EN AC-41000-T6 or EN AC-41000 T6-K?

EN AC-41000-T6, by a small margin. Both rate good for machinability — 68/100 against 62/100 for EN AC-41000 T6-K; for welding the order is EN AC-41000 T6-K first (very good, 80/100) then EN AC-41000-T6 (good, 68/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-41000-T6 and EN AC-41000 T6-K side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.