FabDigitFabDigit

Aluminum EN AC-41000-F vs EN AC-41000-T6

Aluminum · EN AC-41000 temper comparison

EN AC-41000-F and EN AC-41000-T6 are two conditions of the same aluminum grade, EN AC-41000: F (as fabricated) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-41000-T6 is the stronger of the two: yield strength 130 MPa (18.9 ksi) against 75 MPa (10.9 ksi) for EN AC-41000-F, about 73% more; tensile strength follows at 190 MPa (27.6 ksi) vs 145 MPa (21 ksi). EN AC-41000-T6 is harder — 55 HB against 45 HB for EN AC-41000-F — which matters for wear surfaces and threads.

EN AC-41000-T6Choose it when strength drives the design, or when surface hardness matters.

EN AC-41000-F vs EN AC-41000-T6: properties

EN AC-41000-FEN AC-41000-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

71 GPa10.3 Msi
72 GPa10.4 Msi

Shear Modulus

26.5 GPa3.8 Msi
27 GPa3.9 Msi

Bulk Modulus

70 GPa10.2 Msi
71 GPa10.3 Msi

Tensile Strength (Ultimate)

145 MPa21 ksi
190 MPa27.6 ksi

Yield Strength (0.2% offset)

75 MPa10.9 ksi
130 MPa18.9 ksi

Shear Strength

95 MPa13.8 ksi
125 MPa18.1 ksi

Fatigue Strength (Endurance Limit)

50 MPa7.3 ksi
65 MPa9.4 ksi

Charpy V-Notch Impact (RT)

6 J4.4 ft·lbf
5 J3.7 ft·lbf

Hardness, Brinell

45 HB
55 HB

Same in both: Poisson's Ratio 0.33 · Elongation at Break 5% · Compressive Strength 140 MPa20.3 ksi · Fracture Toughness (K_IC) 25 MPa·√m22.8 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 2.67 g/cm³0.1 lb/in³ · Melting Point (Solidus) 610°C1,130 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

180 W/m·K104 BTU/hr·ft·°F
170 W/m·K98.2 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.5 µm/m·K12.5 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

45 % IACS
42 % IACS

Electrical Resistivity

3.8×10⁻⁸ Ω·m1.5 µΩ·in
4.1×10⁻⁸ Ω·m1.61 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 68 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
68 / 100

Weldability

72 / 100
68 / 100

Brazeability / Solderability

45 / 100
40 / 100

Polishability

60 / 100
65 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 160% · Formability (cold) 20 / 100 · Castability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

200 MJ/kg85,985 BTU/lb
205 MJ/kg88,134 BTU/lb

Embodied Carbon (primary production)

12 kg CO₂/kg
12.3 kg CO₂/kg

Same in both: Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-41000

EN AC-41000-F vs EN AC-41000-T6 — frequently asked

Is EN AC-41000-T6 stronger than EN AC-41000-F?

Yes. EN AC-41000-T6 has a typical yield strength of 130 MPa (18.9 ksi) against 75 MPa (10.9 ksi) for EN AC-41000-F — about 73% more. Tensile strength is 190 MPa (27.6 ksi) vs 145 MPa (21 ksi).

Which condition does FabDigit quote by default, F or T6?

T6 is the default EN AC-41000 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, EN AC-41000-F or EN AC-41000-T6?

EN AC-41000-T6, by a small margin. Both rate good for machinability — 68/100 against 62/100 for EN AC-41000-F.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-41000-F and EN AC-41000-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.