FabDigitFabDigit

Aluminum BAlSi-4-F vs BAlSi-4-H14

Aluminum · BAlSi-4 temper comparison

BAlSi-4-F and BAlSi-4-H14 are two conditions of the same aluminum grade, BAlSi-4: F (as fabricated) versus H14 (strain hardened, half hard). The chemistry is identical, so every difference below comes from the condition. BAlSi-4-H14 is the stronger of the two: yield strength 130 MPa (18.9 ksi) against 75 MPa (10.9 ksi) for BAlSi-4-F, about 73% more; tensile strength follows at 195 MPa (28.3 ksi) vs 160 MPa (23.2 ksi). BAlSi-4-H14 is harder — 65 HB against 55 HB for BAlSi-4-F — which matters for wear surfaces and threads.

BAlSi-4-H14Choose it when strength drives the design, or when surface hardness matters.

BAlSi-4-F vs BAlSi-4-H14: properties

BAlSi-4-FBAlSi-4-H14

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

71 GPa10.3 Msi
72 GPa10.4 Msi

Tensile Strength (Ultimate)

160 MPa23.2 ksi
195 MPa28.3 ksi

Yield Strength (0.2% offset)

75 MPa10.9 ksi
130 MPa18.9 ksi

Compressive Strength

170 MPa24.7 ksi
200 MPa29 ksi

Shear Strength

100 MPa14.5 ksi
115 MPa16.7 ksi

Fatigue Strength (Endurance Limit)

55 MPa8 ksi
65 MPa9.4 ksi

Hardness, Brinell

55 HB
65 HB

Hardness, Vickers

60 HV
70 HV

Same in both: Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 73 GPa10.6 Msi · Poisson's Ratio 0.33 · Elongation at Break 3% · Fracture Toughness (K_IC) 14 MPa·√m12.7 ksi·√in · Charpy V-Notch Impact (RT) 3 J2.2 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 2.66 g/cm³0.1 lb/in³ · Melting Point (Solidus) 577°C1,071 °F · Liquidus Temperature 582°C1,080 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

150 W/m·K86.7 BTU/hr·ft·°F
155 W/m·K89.6 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.4 µm/m·K11.3 µin/in·°F · Latent Heat of Fusion 500 J/g215 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

36 % IACS
37 % IACS

Electrical Resistivity

4.79×10⁻⁸ Ω·m1.89 µΩ·in
4.66×10⁻⁸ Ω·m1.83 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

53 / 100
55 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
32 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
32%

Formability (cold)

15 / 100
20 / 100

Same in both: Weldability 85 / 100 · Castability 95 / 100 · Brazeability / Solderability 98 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleBAlSi-4

BAlSi-4-F vs BAlSi-4-H14 — frequently asked

Is BAlSi-4-H14 stronger than BAlSi-4-F?

Yes. BAlSi-4-H14 has a typical yield strength of 130 MPa (18.9 ksi) against 75 MPa (10.9 ksi) for BAlSi-4-F — about 73% more. Tensile strength is 195 MPa (28.3 ksi) vs 160 MPa (23.2 ksi).

Which condition does FabDigit quote by default, F or H14?

AW is the default BAlSi-4 condition in the FabDigit quote flow (neither F nor H14). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose BAlSi-4-F over BAlSi-4-H14?

Pick BAlSi-4-H14 when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in BAlSi-4-F and BAlSi-4-H14 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.