FabDigitFabDigit

Aluminum ADC12-F vs ADC12-T6

Aluminum · ADC12 temper comparison

ADC12-F and ADC12-T6 are two conditions of the same aluminum grade, ADC12: F (as fabricated) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. ADC12-T6 is the stronger of the two: yield strength 260 MPa (37.7 ksi) against 155 MPa (22.5 ksi) for ADC12-F, about 68% more; tensile strength follows at 340 MPa (49.3 ksi) vs 310 MPa (45 ksi). In exchange, ADC12-F is the more ductile: elongation 2.5% versus 1% for ADC12-T6, and ADC12-T6 is harder (110 HB vs 80 HB). ADC12-T6 runs hotter in service (175°C vs 150°C continuous) and ADC12-T6 conducts electricity better (26 % IACS vs 23 % IACS).

ADC12-FChoose it when the part is bent, formed or impact-loaded.

ADC12-T6Choose it when strength drives the design, or when the part sees heat.

ADC12-F vs ADC12-T6: properties

ADC12-FADC12-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

310 MPa45 ksi
340 MPa49.3 ksi

Yield Strength (0.2% offset)

155 MPa22.5 ksi
260 MPa37.7 ksi

Elongation at Break

2.5%
1%

Compressive Strength

320 MPa46.4 ksi
380 MPa55.1 ksi

Shear Strength

190 MPa27.6 ksi
210 MPa30.5 ksi

Fatigue Strength (Endurance Limit)

140 MPa20.3 ksi
150 MPa21.8 ksi

Fracture Toughness (K_IC)

15 MPa·√m13.7 ksi·√in
13 MPa·√m11.8 ksi·√in

Charpy V-Notch Impact (RT)

3 J2.2 ft·lbf
2 J1.5 ft·lbf

Hardness, Brinell

80 HB
110 HB

Hardness, Rockwell B

45 HRB
62 HRB

Hardness, Vickers

85 HV
120 HV

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.74 g/cm³0.1 lb/in³ · Melting Point (Solidus) 515°C959 °F · Liquidus Temperature 582°C1,080 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

96 W/m·K55.5 BTU/hr·ft·°F
105 W/m·K60.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
175°C347 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.1 µm/m·K11.7 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

23 % IACS
26 % IACS

Electrical Resistivity

7.5×10⁻⁸ Ω·m2.95 µΩ·in
6.6×10⁻⁸ Ω·m2.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

42 / 100
40 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

68 / 100
72 / 100

Machinability Rating (AISI 1212 = 100 %)

190%
200%

Weldability

18 / 100
15 / 100

Formability (cold)

8 / 100
4 / 100

Same in both: Castability 95 / 100 · Brazeability / Solderability 20 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 180 MJ/kg77,386 BTU/lb · Embodied Carbon (primary production) 11.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 90%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleADC12

ADC12-F vs ADC12-T6 — frequently asked

Is ADC12-T6 stronger than ADC12-F?

Yes. ADC12-T6 has a typical yield strength of 260 MPa (37.7 ksi) against 155 MPa (22.5 ksi) for ADC12-F — about 68% more. Tensile strength is 340 MPa (49.3 ksi) vs 310 MPa (45 ksi).

Which condition does FabDigit quote by default, F or T6?

F is the default ADC12 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose ADC12-F over ADC12-T6?

Pick ADC12-F when the part is bent, formed or impact-loaded. Pick ADC12-T6 when strength drives the design, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in ADC12-F and ADC12-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.