ADC12-F and ADC12-T5 are two conditions of the same aluminum grade, ADC12: F (as fabricated) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. ADC12-T5 is the stronger of the two: yield strength 200 MPa (29 ksi) against 155 MPa (22.5 ksi) for ADC12-F, about 29% more; tensile strength follows at 330 MPa (47.9 ksi) vs 310 MPa (45 ksi). In exchange, ADC12-F is the more ductile: elongation 2.5% versus 1.5% for ADC12-T5, and ADC12-T5 is harder (90 HB vs 80 HB). ADC12-T5 runs hotter in service (175°C vs 150°C continuous).

ADC12-FChoose it when the part is bent, formed or impact-loaded.

ADC12-T5Choose it when strength drives the design, or when the part sees heat.

ADC12-F vs ADC12-T5: properties

ADC12-FADC12-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

310 MPa45 ksi
330 MPa47.9 ksi

Yield Strength (0.2% offset)

155 MPa22.5 ksi
200 MPa29 ksi

Elongation at Break

2.5%
1.5%

Compressive Strength

320 MPa46.4 ksi
345 MPa50 ksi

Shear Strength

190 MPa27.6 ksi
200 MPa29 ksi

Fatigue Strength (Endurance Limit)

140 MPa20.3 ksi
145 MPa21 ksi

Fracture Toughness (K_IC)

15 MPa·√m13.7 ksi·√in
14 MPa·√m12.7 ksi·√in

Charpy V-Notch Impact (RT)

3 J2.2 ft·lbf
3 J1.8 ft·lbf

Hardness, Brinell

80 HB
90 HB

Hardness, Rockwell B

45 HRB
52 HRB

Hardness, Vickers

85 HV
98 HV

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.74 g/cm³0.1 lb/in³ · Melting Point (Solidus) 515°C959 °F · Liquidus Temperature 582°C1,080 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

96 W/m·K55.5 BTU/hr·ft·°F
100 W/m·K57.8 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
175°C347 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.1 µm/m·K11.7 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

23 % IACS
24.5 % IACS

Electrical Resistivity

7.5×10⁻⁸ Ω·m2.95 µΩ·in
7×10⁻⁸ Ω·m2.76 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

42 / 100
43 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

68 / 100
70 / 100

Machinability Rating (AISI 1212 = 100 %)

190%
195%

Formability (cold)

8 / 100
5 / 100

Same in both: Weldability 18 / 100 · Castability 95 / 100 · Brazeability / Solderability 20 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 180 MJ/kg77,386 BTU/lb · Embodied Carbon (primary production) 11.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 90%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleADC12

ADC12-F vs ADC12-T5 — frequently asked

Is ADC12-T5 stronger than ADC12-F?

Yes. ADC12-T5 has a typical yield strength of 200 MPa (29 ksi) against 155 MPa (22.5 ksi) for ADC12-F — about 29% more. Tensile strength is 330 MPa (47.9 ksi) vs 310 MPa (45 ksi).

Which condition does FabDigit quote by default, F or T5?

F is the default ADC12 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose ADC12-F over ADC12-T5?

Pick ADC12-F when the part is bent, formed or impact-loaded. Pick ADC12-T5 when strength drives the design, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in ADC12-F and ADC12-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.