FabDigitFabDigit

Aluminum AC8C-T5 vs AC8C-T6

Aluminum · AC8C temper comparison

AC8C-T5 and AC8C-T6 are two conditions of the same aluminum grade, AC8C: T5 (cooled from hot working and artificially aged) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. AC8C-T6 is the stronger of the two: yield strength 250 MPa (36.3 ksi) against 175 MPa (25.4 ksi) for AC8C-T5, about 43% more; tensile strength follows at 285 MPa (41.3 ksi) vs 215 MPa (31.2 ksi). In exchange, AC8C-T5 is the more ductile: elongation 1% versus 0.8% for AC8C-T6, and AC8C-T6 is harder (110 HB vs 95 HB). AC8C-T5 conducts heat better (125 W/m·K vs 110 W/m·K).

AC8C-T5Choose it when the part is bent, formed or impact-loaded.

AC8C-T6Choose it when strength drives the design.

AC8C-T5 vs AC8C-T6: properties

AC8C-T5AC8C-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

215 MPa31.2 ksi
285 MPa41.3 ksi

Yield Strength (0.2% offset)

175 MPa25.4 ksi
250 MPa36.3 ksi

Elongation at Break

1%
0.8%

Shear Strength

150 MPa21.8 ksi
195 MPa28.3 ksi

Fatigue Strength (Endurance Limit)

85 MPa12.3 ksi
95 MPa13.8 ksi

Hardness, Brinell

95 HB
110 HB

Same in both: Elastic (Young's) Modulus 80 GPa11.6 Msi · Shear Modulus 30 GPa4.4 Msi · Bulk Modulus 76 GPa11 Msi · Poisson's Ratio 0.33 · Compressive Strength 265 MPa38.4 ksi · Fracture Toughness (K_IC) 16 MPa·√m14.6 ksi·√in · Charpy V-Notch Impact (RT) 2 J1.5 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 2.74 g/cm³0.1 lb/in³ · Melting Point (Solidus) 520°C968 °F · Liquidus Temperature 590°C1,094 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

125 W/m·K72.2 BTU/hr·ft·°F
110 W/m·K63.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

210°C410 °F
200°C392 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.5 µm/m·K11.4 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -60°C-76 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

28 % IACS
24 % IACS

Same in both: Electrical Resistivity 7.2×10⁻⁸ Ω·m2.83 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.8 V · Corrosion Resistance 42 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 60 / 100 · Machinability Rating (AISI 1212 = 100 %) 60% · Weldability 30 / 100 · Formability (cold) 5 / 100 · Castability 82 / 100 · Brazeability / Solderability 20 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 55%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleAC8C

AC8C-T5 vs AC8C-T6 — frequently asked

Is AC8C-T6 stronger than AC8C-T5?

Yes. AC8C-T6 has a typical yield strength of 250 MPa (36.3 ksi) against 175 MPa (25.4 ksi) for AC8C-T5 — about 43% more. Tensile strength is 285 MPa (41.3 ksi) vs 215 MPa (31.2 ksi).

Which condition does FabDigit quote by default, T5 or T6?

T6 is the default AC8C condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose AC8C-T5 over AC8C-T6?

Pick AC8C-T5 when the part is bent, formed or impact-loaded. Pick AC8C-T6 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in AC8C-T5 and AC8C-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.