FabDigitFabDigit

Aluminum AC8B-F vs AC8B-T5

Aluminum · AC8B temper comparison

AC8B-F and AC8B-T5 are two conditions of the same aluminum grade, AC8B: F (as fabricated) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. AC8B-T5 is the stronger of the two: yield strength 180 MPa (26.1 ksi) against 130 MPa (18.9 ksi) for AC8B-F, about 38% more; tensile strength follows at 210 MPa (30.5 ksi) vs 180 MPa (26.1 ksi). In exchange, AC8B-F is the more ductile: elongation 1.5% versus 1% for AC8B-T5, and AC8B-T5 is harder (95 HB vs 85 HB). AC8B-T5 runs hotter in service (250°C vs 200°C continuous).

AC8B-FChoose it when the part is bent, formed or impact-loaded.

AC8B-T5Choose it when strength drives the design, or when the part sees heat.

AC8B-F vs AC8B-T5: properties

AC8B-FAC8B-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

180 MPa26.1 ksi
210 MPa30.5 ksi

Yield Strength (0.2% offset)

130 MPa18.9 ksi
180 MPa26.1 ksi

Elongation at Break

1.5%
1%

Shear Strength

140 MPa20.3 ksi
190 MPa27.6 ksi

Fatigue Strength (Endurance Limit)

65 MPa9.4 ksi
76 MPa11 ksi

Hardness, Brinell

85 HB
95 HB

Same in both: Elastic (Young's) Modulus 82 GPa11.9 Msi · Shear Modulus 31 GPa4.5 Msi · Bulk Modulus 73 GPa10.6 Msi · Poisson's Ratio 0.33 · Compressive Strength 260 MPa37.7 ksi · Fracture Toughness (K_IC) 15 MPa·√m13.7 ksi·√in · Charpy V-Notch Impact (RT) 3 J2.2 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 2.76 g/cm³0.1 lb/in³ · Melting Point (Solidus) 521°C970 °F · Liquidus Temperature 582°C1,080 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

105 W/m·K60.7 BTU/hr·ft·°F
104 W/m·K60.1 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
250°C482 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.7 µm/m·K11.5 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -60°C-76 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

28 % IACS
27 % IACS

Same in both: Electrical Resistivity 6.6×10⁻⁸ Ω·m2.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V · Corrosion Resistance 38 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
52 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 200% · Weldability 22 / 100 · Castability 85 / 100 · Brazeability / Solderability 20 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 75%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleAC8B

AC8B-F vs AC8B-T5 — frequently asked

Is AC8B-T5 stronger than AC8B-F?

Yes. AC8B-T5 has a typical yield strength of 180 MPa (26.1 ksi) against 130 MPa (18.9 ksi) for AC8B-F — about 38% more. Tensile strength is 210 MPa (30.5 ksi) vs 180 MPa (26.1 ksi).

Which condition does FabDigit quote by default, F or T5?

T6 is the default AC8B condition in the FabDigit quote flow (neither F nor T5). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose AC8B-F over AC8B-T5?

Pick AC8B-F when the part is bent, formed or impact-loaded. Pick AC8B-T5 when strength drives the design, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in AC8B-F and AC8B-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.