Aluminum · grade comparison

Aluminum AC2A and ADC12 are both aluminum grades. AC2A is the stronger of the two: yield strength 170 MPa (24.7 ksi) against 155 MPa (22.5 ksi) for ADC12, about 10% more. In exchange, ADC12 is the more ductile: elongation 2.5% versus 2% for AC2A, and AC2A is harder (85 HB vs 80 HB). AC2A runs hotter in service (175°C vs 150°C continuous) and AC2A conducts heat better (110 W/m·K vs 96 W/m·K). On the shop floor, AC2A welds better (fair vs poor).

AC2AChoose it when strength drives the design, or when the part sees heat.

ADC12Choose it when the part is bent, formed or impact-loaded.

AC2A vs ADC12: properties

AC2AADC12

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

74 GPa10.7 Msi
71 GPa10.3 Msi

Shear Modulus

27.5 GPa4 Msi
26.5 GPa3.8 Msi

Bulk Modulus

72 GPa10.4 Msi
69 GPa10 Msi

Tensile Strength (Ultimate)

250 MPa36.3 ksi
310 MPa45 ksi

Yield Strength (0.2% offset)

170 MPa24.7 ksi
155 MPa22.5 ksi

Elongation at Break

2%
2.5%

Shear Strength

165 MPa23.9 ksi
190 MPa27.6 ksi

Fatigue Strength (Endurance Limit)

75 MPa10.9 ksi
140 MPa20.3 ksi

Fracture Toughness (K_IC)

18 MPa·√m16.4 ksi·√in
15 MPa·√m13.7 ksi·√in

Hardness, Brinell

85 HB
80 HB

Compressive Strength

—
320 MPa46.4 ksi

Hardness, Rockwell B

—
45 HRB

Hardness, Vickers

—
85 HV

Same in both: Poisson's Ratio 0.33 · Charpy V-Notch Impact (RT) 3 J2.2 ft·lbf

Physical

Density and transition temperatures.

Density

2.79 g/cm³0.1 lb/in³
2.74 g/cm³0.1 lb/in³

Melting Point (Solidus)

516°C961 °F
515°C959 °F

Liquidus Temperature

604°C1,119 °F
582°C1,080 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

110 W/m·K63.6 BTU/hr·ft·°F
96 W/m·K55.5 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

21.5 µm/m·K11.9 µin/in·°F
21.1 µm/m·K11.7 µin/in·°F

Max Service Temperature (continuous)

175°C347 °F
150°C302 °F

Min Service Temperature

-196°C-321 °F
-50°C-58 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Latent Heat of Fusion 389 J/g167 BTU/lb

Electrical

Conductivity and insulation.

Electrical Conductivity

27 % IACS
23 % IACS

Electrical Resistivity

6.4×10⁻⁸ Ω·m2.52 µΩ·in
7.5×10⁻⁸ Ω·m2.95 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.75 V
-0.78 V

Same in both: Corrosion Resistance 42 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

72 / 100
68 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
190%

Weldability

35 / 100
18 / 100

Formability (cold)

10 / 100
8 / 100

Castability

75 / 100
95 / 100

Brazeability / Solderability

25 / 100
20 / 100

Same in both: Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

200 MJ/kg85,985 BTU/lb
180 MJ/kg77,386 BTU/lb

Embodied Carbon (primary production)

12 kg CO₂/kg
11.5 kg CO₂/kg

Embodied Water

1,150 L/kg138 gal/lb
1,100 L/kg132 gal/lb

Typical Recycled Content

80%
90%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

90 kN·m/kg
113 kN·m/kg

Specific Stiffness (E / density)

26.5 MN·m/kg
25.9 MN·m/kg

Modulus of Resilience

195 kJ/m³
169 kJ/m³

Thermal Diffusivity

40.9 mm²/s
36.4 mm²/s

Thermal Shock Resistance Index

17
20

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleAC2AADC12

Manufacturing and finishing

CapabilityAC2AADC12
Default condition——
Relative cost$$ Standard$$ Standard
Min. machined wall——
Best machined surface——

Both take the same 4 finishes: Electroless Nickel (EN), Epoxy Coating, Gold Plating, Silver Plating.

AC2A vs ADC12 — frequently asked

Is AC2A stronger than ADC12?

Yes. AC2A has a typical yield strength of 170 MPa (24.7 ksi) against 155 MPa (22.5 ksi) for ADC12 — about 10% more. Tensile strength is 250 MPa (36.3 ksi) vs 310 MPa (45 ksi).

Which is cheaper, AC2A or ADC12?

Both sit in the same relative cost tier ($$, standard); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which welds better, AC2A or ADC12?

AC2A. Its weldability rates fair (35/100) against poor (18/100) for ADC12.

Ready to make it?

Upload a CAD file and FabDigit prices the part in AC2A and ADC12 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.