FabDigitFabDigit

Aluminum A360-F vs A360-SR

Aluminum · A360 temper comparison

A360-F and A360-SR are two conditions of the same aluminum grade, A360: F (as fabricated) versus SR (stress relieved). The chemistry is identical, so every difference below comes from the condition. A360-SR is the stronger of the two: yield strength 215 MPa (31.2 ksi) against 165 MPa (23.9 ksi) for A360-F, about 30% more; tensile strength follows at 345 MPa (50 ksi) vs 317 MPa (46 ksi). A360-SR is the more ductile: elongation 8% versus 3.5% for A360-F, and A360-SR is harder (95 HB vs 75 HB). A360-SR conducts heat better (140 W/m·K vs 113 W/m·K). On the shop floor, A360-SR welds better (good vs fair).

A360-SRChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

A360-F vs A360-SR: properties

A360-FA360-SR

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

71 GPa10.3 Msi
70 GPa10.2 Msi

Tensile Strength (Ultimate)

317 MPa46 ksi
345 MPa50 ksi

Yield Strength (0.2% offset)

165 MPa23.9 ksi
215 MPa31.2 ksi

Elongation at Break

3.5%
8%

Compressive Strength

170 MPa24.7 ksi
230 MPa33.4 ksi

Shear Strength

180 MPa26.1 ksi
215 MPa31.2 ksi

Fatigue Strength (Endurance Limit)

138 MPa20 ksi
100 MPa14.5 ksi

Fracture Toughness (K_IC)

18 MPa·√m16.4 ksi·√in
28 MPa·√m25.5 ksi·√in

Charpy V-Notch Impact (RT)

4 J3 ft·lbf
6 J4.4 ft·lbf

Hardness, Brinell

75 HB
95 HB

Hardness, Vickers

82 HV
100 HV

Same in both: Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.63 g/cm³0.1 lb/in³ · Melting Point (Solidus) 557°C1,035 °F · Liquidus Temperature 596°C1,105 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

113 W/m·K65.3 BTU/hr·ft·°F
140 W/m·K80.9 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21 µm/m·K11.7 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

29 % IACS
31 % IACS

Electrical Resistivity

5.9×10⁻⁸ Ω·m2.32 µΩ·in
5.6×10⁻⁸ Ω·m2.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

58 / 100
60 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Weldability

40 / 100
55 / 100

Formability (cold)

10 / 100
15 / 100

Same in both: Machinability 55 / 100 · Castability 92 / 100 · Brazeability / Solderability 25 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleA360

A360-F vs A360-SR — frequently asked

Is A360-SR stronger than A360-F?

Yes. A360-SR has a typical yield strength of 215 MPa (31.2 ksi) against 165 MPa (23.9 ksi) for A360-F — about 30% more. Tensile strength is 345 MPa (50 ksi) vs 317 MPa (46 ksi).

Which condition does FabDigit quote by default, F or SR?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which welds better, A360-F or A360-SR?

A360-SR. Its weldability rates good (55/100) against fair (40/100) for A360-F.

Ready to make it?

Upload a CAD file and FabDigit prices the part in A360-F and A360-SR side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.