FabDigitFabDigit

Aluminum A360-SR vs A360-T6

Aluminum · A360 temper comparison

A360-SR and A360-T6 are two conditions of the same aluminum grade, A360: SR (stress relieved) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. A360-T6 is the stronger of the two: yield strength 235 MPa (34.1 ksi) against 215 MPa (31.2 ksi) for A360-SR, about 9% more. A360-T6 is harder — 100 HB against 95 HB for A360-SR — which matters for wear surfaces and threads. A360-T6 conducts electricity better (35 % IACS vs 31 % IACS). On the shop floor, A360-SR welds better (good vs fair).

A360-SRChoose it when it will be welded.

A360-T6Choose it when strength drives the design, or when surface hardness matters.

A360-SR vs A360-T6: properties

A360-SRA360-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

345 MPa50 ksi
335 MPa48.6 ksi

Yield Strength (0.2% offset)

215 MPa31.2 ksi
235 MPa34.1 ksi

Compressive Strength

230 MPa33.4 ksi
250 MPa36.3 ksi

Shear Strength

215 MPa31.2 ksi
210 MPa30.5 ksi

Fatigue Strength (Endurance Limit)

100 MPa14.5 ksi
110 MPa16 ksi

Fracture Toughness (K_IC)

28 MPa·√m25.5 ksi·√in
30 MPa·√m27.3 ksi·√in

Hardness, Brinell

95 HB
100 HB

Hardness, Vickers

100 HV
105 HV

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33 · Elongation at Break 8% · Charpy V-Notch Impact (RT) 6 J4.4 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 2.63 g/cm³0.1 lb/in³ · Melting Point (Solidus) 557°C1,035 °F · Liquidus Temperature 596°C1,105 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

140 W/m·K80.9 BTU/hr·ft·°F
155 W/m·K89.6 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21 µm/m·K11.7 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

31 % IACS
35 % IACS

Electrical Resistivity

5.6×10⁻⁸ Ω·m2.2 µΩ·in
4.9×10⁻⁸ Ω·m1.93 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

60 / 100
57 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
58 / 100

Weldability

55 / 100
45 / 100

Formability (cold)

15 / 100
12 / 100

Same in both: Castability 92 / 100 · Brazeability / Solderability 25 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleA360

A360-SR vs A360-T6 — frequently asked

Is A360-T6 stronger than A360-SR?

Yes. A360-T6 has a typical yield strength of 235 MPa (34.1 ksi) against 215 MPa (31.2 ksi) for A360-SR — about 9% more. Tensile strength is 335 MPa (48.6 ksi) vs 345 MPa (50 ksi).

Which condition does FabDigit quote by default, SR or T6?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which welds better, A360-SR or A360-T6?

A360-SR. Its weldability rates good (55/100) against fair (45/100) for A360-T6.

Ready to make it?

Upload a CAD file and FabDigit prices the part in A360-SR and A360-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.