Aluminum A2024-RAM2-AB vs A2024-RAM2-T6
Aluminum · A2024-RAM2 temper comparison
A2024-RAM2-AB and A2024-RAM2-T6 are two conditions of the same aluminum grade, A2024-RAM2: AB (as built (as printed)) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. A2024-RAM2-T6 is the stronger of the two: yield strength 430 MPa (62.4 ksi) against 300 MPa (43.5 ksi) for A2024-RAM2-AB, about 43% more; tensile strength follows at 500 MPa (72.5 ksi) vs 400 MPa (58 ksi). In exchange, A2024-RAM2-AB is the more ductile: elongation 7% versus 6% for A2024-RAM2-T6, and A2024-RAM2-T6 is harder (140 HB vs 110 HB). A2024-RAM2-T6 runs hotter in service (150°C vs 120°C continuous) and A2024-RAM2-T6 conducts heat better (120 W/m·K vs 105 W/m·K).
A2024-RAM2-ABChoose it when the part is bent, formed or impact-loaded.
A2024-RAM2-T6Choose it when strength drives the design, or when the part sees heat.
A2024-RAM2-AB vs A2024-RAM2-T6: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all aluminum grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all aluminum grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Fatigue Strength (Endurance Limit)
Hardness, Brinell
Hardness, Vickers
Same in both: Elastic (Young's) Modulus 78 GPa11.3 Msi · Shear Modulus 29 GPa4.2 Msi · Bulk Modulus 76 GPa11 Msi · Poisson's Ratio 0.33 · Compressive Strength 440 MPa63.8 ksi · Shear Strength 295 MPa42.8 ksi · Fracture Toughness (K_IC) 22 MPa·√m20 ksi·√in · Hardness, Rockwell B 82 HRB
Physical
Density and transition temperatures.
Same in both: Density 2.78 g/cm³0.1 lb/in³ · Melting Point (Solidus) 502°C936 °F · Liquidus Temperature 638°C1,180 °F
Thermal
How each material carries heat and how hot it can run.
Thermal Conductivity
Max Service Temperature (continuous)
Same in both: Specific Heat Capacity 875 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F
Electrical
Conductivity and insulation.
Electrical Conductivity
Same in both: Electrical Resistivity 5.4×10⁻⁸ Ω·m2.13 µΩ·in
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V · Corrosion Resistance 33 / 100
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Same in both: Machinability Rating (AISI 1212 = 100 %) 130% · Weldability 25 / 100 · Formability (cold) 15 / 100 · Brazeability / Solderability 15 / 100 · Polishability 55 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 260 MJ/kg111,780 BTU/lb · Embodied Carbon (primary production) 15 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 5%
Strength versus weight
Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
A2024-RAM2-AB vs A2024-RAM2-T6 — frequently asked
Is A2024-RAM2-T6 stronger than A2024-RAM2-AB?
Yes. A2024-RAM2-T6 has a typical yield strength of 430 MPa (62.4 ksi) against 300 MPa (43.5 ksi) for A2024-RAM2-AB — about 43% more. Tensile strength is 500 MPa (72.5 ksi) vs 400 MPa (58 ksi).
Which condition does FabDigit quote by default, AB or T6?
T6 is the default A2024-RAM2 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which is easier to machine, A2024-RAM2-AB or A2024-RAM2-T6?
A2024-RAM2-AB, by a small margin. Both rate good for machinability — 60/100 against 55/100 for A2024-RAM2-T6.
Ready to make it?
Upload a CAD file and FabDigit prices the part in A2024-RAM2-AB and A2024-RAM2-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.