FabDigitFabDigit

Aluminum 8176-H22 vs 8176-H26

Aluminum · 8176 temper comparison

8176-H22 and 8176-H26 are two conditions of the same aluminum grade, 8176: H22 (strain hardened and partially annealed, quarter hard) versus H26 (strain hardened and partially annealed, three-quarter hard). The chemistry is identical, so every difference below comes from the condition. 8176-H26 is the stronger of the two: yield strength 100 MPa (14.5 ksi) against 62 MPa (8.99 ksi) for 8176-H22, about 61% more; tensile strength follows at 122 MPa (17.7 ksi) vs 90 MPa (13.1 ksi). In exchange, 8176-H22 is the more ductile: elongation 20% versus 12% for 8176-H26, and 8176-H26 is harder (34 HB vs 25 HB).

8176-H22Choose it when the part is bent, formed or impact-loaded.

8176-H26Choose it when strength drives the design.

8176-H22 vs 8176-H26: properties

8176-H228176-H26

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

90 MPa13.1 ksi
122 MPa17.7 ksi

Yield Strength (0.2% offset)

62 MPa9 ksi
100 MPa14.5 ksi

Elongation at Break

20%
12%

Shear Strength

60 MPa8.7 ksi
75 MPa10.9 ksi

Fatigue Strength (Endurance Limit)

38 MPa5.5 ksi
48 MPa7 ksi

Hardness, Brinell

25 HB
34 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 645°C1,193 °F · Liquidus Temperature 655°C1,211 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

231 W/m·K133 BTU/hr·ft·°F
230 W/m·K133 BTU/hr·ft·°F

Max Service Temperature (continuous)

100°C212 °F
95°C203 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

61.5 % IACS
61 % IACS

Electrical Resistivity

2.8×10⁻⁸ Ω·m1.1 µΩ·in
2.83×10⁻⁸ Ω·m1.11 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.84 V · Corrosion Resistance 68 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

27 / 100
34 / 100

Machinability Rating (AISI 1212 = 100 %)

85%
92%

Weldability

90 / 100
88 / 100

Formability (cold)

88 / 100
66 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale8176

8176-H22 vs 8176-H26 — frequently asked

Is 8176-H26 stronger than 8176-H22?

Yes. 8176-H26 has a typical yield strength of 100 MPa (14.5 ksi) against 62 MPa (8.99 ksi) for 8176-H22 — about 61% more. Tensile strength is 122 MPa (17.7 ksi) vs 90 MPa (13.1 ksi).

Which condition does FabDigit quote by default, H22 or H26?

H24 is the default 8176 condition in the FabDigit quote flow (neither H22 nor H26). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 8176-H22 or 8176-H26?

8176-H26, by a small margin. Both rate poor for machinability — 34/100 against 27/100 for 8176-H22.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 8176-H22 and 8176-H26 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.