FabDigitFabDigit

Aluminum 8176-H14 vs 8176-H22

Aluminum · 8176 temper comparison

8176-H14 and 8176-H22 are two conditions of the same aluminum grade, 8176: H14 (strain hardened, half hard) versus H22 (strain hardened and partially annealed, quarter hard). The chemistry is identical, so every difference below comes from the condition. 8176-H14 is the stronger of the two: yield strength 92 MPa (13.3 ksi) against 62 MPa (8.99 ksi) for 8176-H22, about 48% more; tensile strength follows at 105 MPa (15.2 ksi) vs 90 MPa (13.1 ksi). In exchange, 8176-H22 is the more ductile: elongation 20% versus 12% for 8176-H14, and 8176-H14 is harder (30 HB vs 25 HB). 8176-H22 runs hotter in service (100°C vs 90°C continuous).

8176-H14Choose it when strength drives the design.

8176-H22Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

8176-H14 vs 8176-H22: properties

8176-H148176-H22

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

105 MPa15.2 ksi
90 MPa13.1 ksi

Yield Strength (0.2% offset)

92 MPa13.3 ksi
62 MPa9 ksi

Elongation at Break

12%
20%

Shear Strength

66 MPa9.6 ksi
60 MPa8.7 ksi

Fatigue Strength (Endurance Limit)

44 MPa6.4 ksi
38 MPa5.5 ksi

Hardness, Brinell

30 HB
25 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 645°C1,193 °F · Liquidus Temperature 655°C1,211 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

230 W/m·K133 BTU/hr·ft·°F
231 W/m·K133 BTU/hr·ft·°F

Max Service Temperature (continuous)

90°C194 °F
100°C212 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

61 % IACS
61.5 % IACS

Electrical Resistivity

2.83×10⁻⁸ Ω·m1.11 µΩ·in
2.8×10⁻⁸ Ω·m1.1 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.84 V · Corrosion Resistance 68 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
27 / 100

Machinability Rating (AISI 1212 = 100 %)

90%
85%

Formability (cold)

72 / 100
88 / 100

Same in both: Weldability 90 / 100 · Brazeability / Solderability 60 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale8176

8176-H14 vs 8176-H22 — frequently asked

Is 8176-H14 stronger than 8176-H22?

Yes. 8176-H14 has a typical yield strength of 92 MPa (13.3 ksi) against 62 MPa (8.99 ksi) for 8176-H22 — about 48% more. Tensile strength is 105 MPa (15.2 ksi) vs 90 MPa (13.1 ksi).

Which condition does FabDigit quote by default, H14 or H22?

H24 is the default 8176 condition in the FabDigit quote flow (neither H14 nor H22). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 8176-H14 or 8176-H22?

8176-H14, by a small margin. Both rate poor for machinability — 32/100 against 27/100 for 8176-H22.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 8176-H14 and 8176-H22 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.