8079-H14 and 8079-H22 are two conditions of the same aluminum grade, 8079: H14 (strain hardened, half hard) versus H22 (strain hardened and partially annealed, quarter hard). The chemistry is identical, so every difference below comes from the condition. 8079-H14 is the stronger of the two: yield strength 105 MPa (15.2 ksi) against 75 MPa (10.9 ksi) for 8079-H22, about 40% more; tensile strength follows at 125 MPa (18.1 ksi) vs 105 MPa (15.2 ksi). In exchange, 8079-H22 is the more ductile: elongation 10% versus 6% for 8079-H14, and 8079-H14 is harder (35 HB vs 30 HB). 8079-H22 runs hotter in service (150°C vs 130°C continuous).

8079-H14Choose it when strength drives the design.

8079-H22Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

8079-H14 vs 8079-H22: properties

8079-H148079-H22

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

125 MPa18.1 ksi
105 MPa15.2 ksi

Yield Strength (0.2% offset)

105 MPa15.2 ksi
75 MPa10.9 ksi

Elongation at Break

6%
10%

Shear Strength

78 MPa11.3 ksi
70 MPa10.2 ksi

Fatigue Strength (Endurance Limit)

45 MPa6.5 ksi
40 MPa5.8 ksi

Hardness, Brinell

35 HB
30 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.72 g/cm³0.1 lb/in³ · Melting Point (Solidus) 645°C1,193 °F · Liquidus Temperature 655°C1,211 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

220 W/m·K127 BTU/hr·ft·°F
222 W/m·K128 BTU/hr·ft·°F

Max Service Temperature (continuous)

130°C266 °F
150°C302 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

57 % IACS
58 % IACS

Electrical Resistivity

3.02×10⁻⁸ Ω·m1.19 µΩ·in
2.97×10⁻⁸ Ω·m1.17 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 72 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
32 / 100

Machinability Rating (AISI 1212 = 100 %)

35%
32%

Weldability

70 / 100
75 / 100

Formability (cold)

70 / 100
85 / 100

Same in both: Castability 60 / 100 · Brazeability / Solderability 55 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale8079

8079-H14 vs 8079-H22 — frequently asked

Is 8079-H14 stronger than 8079-H22?

Yes. 8079-H14 has a typical yield strength of 105 MPa (15.2 ksi) against 75 MPa (10.9 ksi) for 8079-H22 — about 40% more. Tensile strength is 125 MPa (18.1 ksi) vs 105 MPa (15.2 ksi).

Which condition does FabDigit quote by default, H14 or H22?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which welds better, 8079-H14 or 8079-H22?

8079-H22. Its weldability rates very good (75/100) against very good (70/100) for 8079-H14.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 8079-H14 and 8079-H22 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.