8079-H14 and 8079-H19 are two conditions of the same aluminum grade, 8079: H14 (strain hardened, half hard) versus H19 (strain hardened, extra hard). The chemistry is identical, so every difference below comes from the condition. 8079-H19 is the stronger of the two: yield strength 160 MPa (23.2 ksi) against 105 MPa (15.2 ksi) for 8079-H14, about 52% more; tensile strength follows at 175 MPa (25.4 ksi) vs 125 MPa (18.1 ksi). In exchange, 8079-H14 is the more ductile: elongation 6% versus 2% for 8079-H19, and 8079-H19 is harder (47 HB vs 35 HB). 8079-H14 runs hotter in service (130°C vs 110°C continuous).

8079-H14Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

8079-H19Choose it when strength drives the design.

8079-H14 vs 8079-H19: properties

8079-H148079-H19

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

125 MPa18.1 ksi
175 MPa25.4 ksi

Yield Strength (0.2% offset)

105 MPa15.2 ksi
160 MPa23.2 ksi

Elongation at Break

6%
2%

Shear Strength

78 MPa11.3 ksi
100 MPa14.5 ksi

Fatigue Strength (Endurance Limit)

45 MPa6.5 ksi
55 MPa8 ksi

Hardness, Brinell

35 HB
47 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.72 g/cm³0.1 lb/in³ · Melting Point (Solidus) 645°C1,193 °F · Liquidus Temperature 655°C1,211 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

220 W/m·K127 BTU/hr·ft·°F
218 W/m·K126 BTU/hr·ft·°F

Max Service Temperature (continuous)

130°C266 °F
110°C230 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

57 % IACS
56.5 % IACS

Electrical Resistivity

3.02×10⁻⁸ Ω·m1.19 µΩ·in
3.05×10⁻⁸ Ω·m1.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

72 / 100
71 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

35%
40%

Weldability

70 / 100
65 / 100

Formability (cold)

70 / 100
40 / 100

Same in both: Castability 60 / 100 · Brazeability / Solderability 55 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale8079

8079-H14 vs 8079-H19 — frequently asked

Is 8079-H19 stronger than 8079-H14?

Yes. 8079-H19 has a typical yield strength of 160 MPa (23.2 ksi) against 105 MPa (15.2 ksi) for 8079-H14 — about 52% more. Tensile strength is 175 MPa (25.4 ksi) vs 125 MPa (18.1 ksi).

Which condition does FabDigit quote by default, H14 or H19?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 8079-H14 or 8079-H19?

8079-H19, by a small margin. Both rate fair for machinability — 40/100 against 35/100 for 8079-H14; for welding the order is 8079-H14 first (very good, 70/100) then 8079-H19 (good, 65/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 8079-H14 and 8079-H19 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.