FabDigitFabDigit

Aluminum 8079-H19 vs 8079-H24

Aluminum · 8079 temper comparison

8079-H19 and 8079-H24 are two conditions of the same aluminum grade, 8079: H19 (strain hardened, extra hard) versus H24 (strain hardened and partially annealed, half hard). The chemistry is identical, so every difference below comes from the condition. 8079-H19 is the stronger of the two: yield strength 160 MPa (23.2 ksi) against 100 MPa (14.5 ksi) for 8079-H24, about 60% more; tensile strength follows at 175 MPa (25.4 ksi) vs 125 MPa (18.1 ksi). In exchange, 8079-H24 is the more ductile: elongation 8% versus 2% for 8079-H19, and 8079-H19 is harder (47 HB vs 34 HB). 8079-H24 runs hotter in service (130°C vs 110°C continuous).

8079-H19Choose it when strength drives the design.

8079-H24Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

8079-H19 vs 8079-H24: properties

8079-H198079-H24

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

175 MPa25.4 ksi
125 MPa18.1 ksi

Yield Strength (0.2% offset)

160 MPa23.2 ksi
100 MPa14.5 ksi

Elongation at Break

2%
8%

Shear Strength

100 MPa14.5 ksi
78 MPa11.3 ksi

Fatigue Strength (Endurance Limit)

55 MPa8 ksi
45 MPa6.5 ksi

Hardness, Brinell

47 HB
34 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.72 g/cm³0.1 lb/in³ · Melting Point (Solidus) 645°C1,193 °F · Liquidus Temperature 655°C1,211 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

218 W/m·K126 BTU/hr·ft·°F
221 W/m·K128 BTU/hr·ft·°F

Max Service Temperature (continuous)

110°C230 °F
130°C266 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

56.5 % IACS
57.5 % IACS

Electrical Resistivity

3.05×10⁻⁸ Ω·m1.2 µΩ·in
3×10⁻⁸ Ω·m1.18 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

71 / 100
72 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
34 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
34%

Weldability

65 / 100
72 / 100

Formability (cold)

40 / 100
75 / 100

Same in both: Castability 60 / 100 · Brazeability / Solderability 55 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale8079

8079-H19 vs 8079-H24 — frequently asked

Is 8079-H19 stronger than 8079-H24?

Yes. 8079-H19 has a typical yield strength of 160 MPa (23.2 ksi) against 100 MPa (14.5 ksi) for 8079-H24 — about 60% more. Tensile strength is 175 MPa (25.4 ksi) vs 125 MPa (18.1 ksi).

Which condition does FabDigit quote by default, H19 or H24?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 8079-H19 or 8079-H24?

8079-H19. Its machinability rates fair (40/100) against poor (34/100) for 8079-H24; for welding the order is 8079-H24 first (very good, 72/100) then 8079-H19 (good, 65/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 8079-H19 and 8079-H24 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.