FabDigitFabDigit

Aluminum 6360-O vs 6360-T1

Aluminum · 6360 temper comparison

6360-O and 6360-T1 are two conditions of the same aluminum grade, 6360: O (annealed) versus T1 (cooled from hot working and naturally aged). The chemistry is identical, so every difference below comes from the condition. 6360-T1 is the stronger of the two: yield strength 70 MPa (10.2 ksi) against 50 MPa (7.25 ksi) for 6360-O, about 40% more; tensile strength follows at 130 MPa (18.9 ksi) vs 105 MPa (15.2 ksi). In exchange, 6360-O is the more ductile: elongation 27% versus 20% for 6360-T1, and 6360-T1 is harder (45 HB vs 28 HB). 6360-O runs hotter in service (200°C vs 120°C continuous) and 6360-O conducts heat better (218 W/m·K vs 190 W/m·K). On the shop floor, 6360-T1 machines more easily (fair vs poor).

6360-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

6360-T1Choose it when strength drives the design, or when the part is machined in volume.

6360-O vs 6360-T1: properties

6360-O6360-T1

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

105 MPa15.2 ksi
130 MPa18.9 ksi

Yield Strength (0.2% offset)

50 MPa7.3 ksi
70 MPa10.2 ksi

Elongation at Break

27%
20%

Compressive Strength

50 MPa7.3 ksi
70 MPa10.2 ksi

Shear Strength

70 MPa10.2 ksi
90 MPa13.1 ksi

Fatigue Strength (Endurance Limit)

40 MPa5.8 ksi
50 MPa7.3 ksi

Fracture Toughness (K_IC)

40 MPa·√m36.4 ksi·√in
35 MPa·√m31.9 ksi·√in

Hardness, Brinell

28 HB
45 HB

Hardness, Vickers

32 HV
50 HV

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 600°C1,112 °F · Liquidus Temperature 653°C1,207 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

218 W/m·K126 BTU/hr·ft·°F
190 W/m·K110 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
120°C248 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 393 J/g169 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

58 % IACS
50 % IACS

Electrical Resistivity

2.97×10⁻⁸ Ω·m1.17 µΩ·in
3.45×10⁻⁸ Ω·m1.36 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

75 / 100
73 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

100%
140%

Weldability

95 / 100
90 / 100

Formability (cold)

95 / 100
88 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 55 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6360

6360-O vs 6360-T1 — frequently asked

Is 6360-T1 stronger than 6360-O?

Yes. 6360-T1 has a typical yield strength of 70 MPa (10.2 ksi) against 50 MPa (7.25 ksi) for 6360-O — about 40% more. Tensile strength is 130 MPa (18.9 ksi) vs 105 MPa (15.2 ksi).

Which condition does FabDigit quote by default, O or T1?

T6 is the default 6360 condition in the FabDigit quote flow (neither O nor T1). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 6360-O or 6360-T1?

6360-T1. Its machinability rates fair (40/100) against poor (30/100) for 6360-O; for welding the order is 6360-O first (excellent, 95/100) then 6360-T1 (excellent, 90/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6360-O and 6360-T1 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.