FabDigitFabDigit

Aluminum 6253-F vs 6253-T6

Aluminum · 6253 temper comparison

6253-F and 6253-T6 are two conditions of the same aluminum grade, 6253: F (as fabricated) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. 6253-T6 is the stronger of the two: yield strength 220 MPa (31.9 ksi) against 90 MPa (13.1 ksi) for 6253-F, about 144% more; tensile strength follows at 255 MPa (37 ksi) vs 160 MPa (23.2 ksi). In exchange, 6253-F is the more ductile: elongation 20% versus 13% for 6253-T6, and 6253-T6 is harder (80 HB vs 45 HB). 6253-F conducts electricity better (46 % IACS vs 40 % IACS). On the shop floor, 6253-T6 machines more easily (good vs fair) and 6253-F welds better (very good vs good).

6253-FChoose it when the part is bent, formed or impact-loaded, or when it will be welded.

6253-T6Choose it when strength drives the design, or when the part is machined in volume.

6253-F vs 6253-T6: properties

6253-F6253-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

160 MPa23.2 ksi
255 MPa37 ksi

Yield Strength (0.2% offset)

90 MPa13.1 ksi
220 MPa31.9 ksi

Elongation at Break

20%
13%

Shear Strength

105 MPa15.2 ksi
165 MPa23.9 ksi

Fatigue Strength (Endurance Limit)

55 MPa8 ksi
90 MPa13.1 ksi

Hardness, Brinell

45 HB
80 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 590°C1,094 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

180 W/m·K104 BTU/hr·ft·°F
165 W/m·K95.3 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 895 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

46 % IACS
40 % IACS

Electrical Resistivity

3.75×10⁻⁸ Ω·m1.48 µΩ·in
4.3×10⁻⁸ Ω·m1.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

62 / 100
60 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.9 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
65 / 100

Weldability

75 / 100
65 / 100

Formability (cold)

70 / 100
45 / 100

Same in both: Brazeability / Solderability 50 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 13 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6253

6253-F vs 6253-T6 — frequently asked

Is 6253-T6 stronger than 6253-F?

Yes. 6253-T6 has a typical yield strength of 220 MPa (31.9 ksi) against 90 MPa (13.1 ksi) for 6253-F — about 144% more. Tensile strength is 255 MPa (37 ksi) vs 160 MPa (23.2 ksi).

Which condition does FabDigit quote by default, F or T6?

T6 is the default 6253 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 6253-F or 6253-T6?

6253-T6. Its machinability rates good (65/100) against fair (45/100) for 6253-F; for welding the order is 6253-F first (very good, 75/100) then 6253-T6 (good, 65/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6253-F and 6253-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.