FabDigitFabDigit

Aluminum 6106-T5 vs 6106-T6

Aluminum · 6106 temper comparison

6106-T5 and 6106-T6 are two conditions of the same aluminum grade, 6106: T5 (cooled from hot working and artificially aged) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. 6106-T6 is the stronger of the two: yield strength 220 MPa (31.9 ksi) against 185 MPa (26.8 ksi) for 6106-T5, about 19% more; tensile strength follows at 265 MPa (38.4 ksi) vs 225 MPa (32.6 ksi). 6106-T6 is the more ductile: elongation 10% versus 9% for 6106-T5, and 6106-T6 is harder (80 HB vs 70 HB).

6106-T6Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

6106-T5 vs 6106-T6: properties

6106-T56106-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

225 MPa32.6 ksi
265 MPa38.4 ksi

Yield Strength (0.2% offset)

185 MPa26.8 ksi
220 MPa31.9 ksi

Elongation at Break

9%
10%

Shear Strength

145 MPa21 ksi
160 MPa23.2 ksi

Fatigue Strength (Endurance Limit)

75 MPa10.9 ksi
85 MPa12.3 ksi

Hardness, Brinell

70 HB
80 HB

Same in both: Elastic (Young's) Modulus 69.5 GPa10.1 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33 · Compressive Strength 220 MPa31.9 ksi · Fracture Toughness (K_IC) 29 MPa·√m26.4 ksi·√in · Hardness, Vickers 85 HV

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 615°C1,139 °F · Liquidus Temperature 655°C1,211 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

195 W/m·K113 BTU/hr·ft·°F
190 W/m·K110 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 393 J/g169 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

50 % IACS
49 % IACS

Same in both: Electrical Resistivity 3.5×10⁻⁸ Ω·m1.38 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.82 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

47 / 100
50 / 100

Formability (cold)

45 / 100
40 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 130% · Weldability 80 / 100 · Brazeability / Solderability 45 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6106

6106-T5 vs 6106-T6 — frequently asked

Is 6106-T6 stronger than 6106-T5?

Yes. 6106-T6 has a typical yield strength of 220 MPa (31.9 ksi) against 185 MPa (26.8 ksi) for 6106-T5 — about 19% more. Tensile strength is 265 MPa (38.4 ksi) vs 225 MPa (32.6 ksi).

Which condition does FabDigit quote by default, T5 or T6?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

When should I choose 6106-T5 over 6106-T6?

Pick 6106-T6 when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6106-T5 and 6106-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.