FabDigitFabDigit

Aluminum 6106-T4 vs 6106-T6

Aluminum · 6106 temper comparison

6106-T4 and 6106-T6 are two conditions of the same aluminum grade, 6106: T4 (solution heat treated and naturally aged) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. 6106-T6 is the stronger of the two: yield strength 220 MPa (31.9 ksi) against 105 MPa (15.2 ksi) for 6106-T4, about 110% more; tensile strength follows at 265 MPa (38.4 ksi) vs 185 MPa (26.8 ksi). In exchange, 6106-T4 is the more ductile: elongation 18% versus 10% for 6106-T6, and 6106-T6 is harder (80 HB vs 55 HB). 6106-T6 runs hotter in service (150°C vs 120°C continuous) and 6106-T6 conducts electricity better (49 % IACS vs 44 % IACS). On the shop floor, 6106-T6 machines more easily (50 vs 40 out of 100).

6106-T4Choose it when the part is bent, formed or impact-loaded.

6106-T6Choose it when strength drives the design, or when the part sees heat.

6106-T4 vs 6106-T6: properties

6106-T46106-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

185 MPa26.8 ksi
265 MPa38.4 ksi

Yield Strength (0.2% offset)

105 MPa15.2 ksi
220 MPa31.9 ksi

Elongation at Break

18%
10%

Compressive Strength

105 MPa15.2 ksi
220 MPa31.9 ksi

Shear Strength

120 MPa17.4 ksi
160 MPa23.2 ksi

Fatigue Strength (Endurance Limit)

60 MPa8.7 ksi
85 MPa12.3 ksi

Fracture Toughness (K_IC)

38 MPa·√m34.6 ksi·√in
29 MPa·√m26.4 ksi·√in

Hardness, Brinell

55 HB
80 HB

Hardness, Vickers

59 HV
85 HV

Same in both: Elastic (Young's) Modulus 69.5 GPa10.1 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 615°C1,139 °F · Liquidus Temperature 655°C1,211 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

175 W/m·K101 BTU/hr·ft·°F
190 W/m·K110 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
150°C302 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 393 J/g169 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

44 % IACS
49 % IACS

Electrical Resistivity

3.92×10⁻⁸ Ω·m1.54 µΩ·in
3.5×10⁻⁸ Ω·m1.38 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

66 / 100
65 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.82 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

105%
130%

Weldability

85 / 100
80 / 100

Formability (cold)

75 / 100
40 / 100

Same in both: Brazeability / Solderability 45 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6106

6106-T4 vs 6106-T6 — frequently asked

Is 6106-T6 stronger than 6106-T4?

Yes. 6106-T6 has a typical yield strength of 220 MPa (31.9 ksi) against 105 MPa (15.2 ksi) for 6106-T4 — about 110% more. Tensile strength is 265 MPa (38.4 ksi) vs 185 MPa (26.8 ksi).

Which condition does FabDigit quote by default, T4 or T6?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 6106-T4 or 6106-T6?

6106-T6, by a small margin. Both rate fair for machinability — 50/100 against 40/100 for 6106-T4; for welding the order is 6106-T4 first (excellent, 85/100) then 6106-T6 (very good, 80/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6106-T4 and 6106-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.