5654-H32 and 5654-H38 are two conditions of the same aluminum grade, 5654: H32 (strain hardened and stabilized, quarter hard) versus H38 (strain hardened and stabilized, full hard). The chemistry is identical, so every difference below comes from the condition. 5654-H38 is the stronger of the two: yield strength 270 MPa (39.2 ksi) against 205 MPa (29.7 ksi) for 5654-H32, about 32% more; tensile strength follows at 330 MPa (47.9 ksi) vs 270 MPa (39.2 ksi). In exchange, 5654-H32 is the more ductile: elongation 15% versus 10% for 5654-H38, and 5654-H38 is harder (80 HB vs 67 HB).

5654-H32Choose it when the part is bent, formed or impact-loaded.

5654-H38Choose it when strength drives the design.

5654-H32 vs 5654-H38: properties

5654-H325654-H38

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

270 MPa39.2 ksi
330 MPa47.9 ksi

Yield Strength (0.2% offset)

205 MPa29.7 ksi
270 MPa39.2 ksi

Elongation at Break

15%
10%

Shear Strength

165 MPa23.9 ksi
190 MPa27.6 ksi

Fatigue Strength (Endurance Limit)

125 MPa18.1 ksi
145 MPa21 ksi

Hardness, Brinell

67 HB
80 HB

Same in both: Elastic (Young's) Modulus 70.3 GPa10.2 Msi · Shear Modulus 26.4 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33 · Hardness, Rockwell B 25 HRB

Physical

Density and transition temperatures.

Same in both: Density 2.66 g/cm³0.1 lb/in³ · Melting Point (Solidus) 593°C1,099 °F · Liquidus Temperature 643°C1,189 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 127 W/m·K73.4 BTU/hr·ft·°F · Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.9 µm/m·K13.3 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Max Service Temperature (continuous) 65°C149 °F · Min Service Temperature -270°C-454 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

32.3 % IACS
32.1 % IACS

Same in both: Electrical Resistivity 5.4×10⁻⁸ Ω·m2.13 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

85 / 100
80 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.87 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

42 / 100
50 / 100

Formability (cold)

78 / 100
40 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 92 / 100 · Brazeability / Solderability 20 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5654

5654-H32 vs 5654-H38 — frequently asked

Is 5654-H38 stronger than 5654-H32?

Yes. 5654-H38 has a typical yield strength of 270 MPa (39.2 ksi) against 205 MPa (29.7 ksi) for 5654-H32 — about 32% more. Tensile strength is 330 MPa (47.9 ksi) vs 270 MPa (39.2 ksi).

Which condition does FabDigit quote by default, H32 or H38?

O is the default 5654 condition in the FabDigit quote flow (neither H32 nor H38). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 5654-H32 or 5654-H38?

5654-H38, by a small margin. Both rate fair for machinability — 50/100 against 42/100 for 5654-H32.