FabDigitFabDigit

Aluminum 5654-AW vs 5654-H32

Aluminum · 5654 temper comparison

5654-AW and 5654-H32 are two conditions of the same aluminum grade, 5654: AW (as-welded deposit) versus H32 (strain hardened and stabilized, quarter hard). The chemistry is identical, so every difference below comes from the condition. 5654-H32 is the stronger of the two: yield strength 205 MPa (29.7 ksi) against 105 MPa (15.2 ksi) for 5654-AW, about 95% more; tensile strength follows at 270 MPa (39.2 ksi) vs 215 MPa (31.2 ksi). In exchange, 5654-AW is the more ductile: elongation 17% versus 15% for 5654-H32, and 5654-H32 is harder (67 HB vs 52 HB).

5654-AWChoose it when the part is bent, formed or impact-loaded.

5654-H32Choose it when strength drives the design.

5654-AW vs 5654-H32: properties

5654-AW5654-H32

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

215 MPa31.2 ksi
270 MPa39.2 ksi

Yield Strength (0.2% offset)

105 MPa15.2 ksi
205 MPa29.7 ksi

Elongation at Break

17%
15%

Shear Strength

117 MPa17 ksi
165 MPa23.9 ksi

Fatigue Strength (Endurance Limit)

85 MPa12.3 ksi
125 MPa18.1 ksi

Hardness, Brinell

52 HB
67 HB

Hardness, Rockwell B

20 HRB
25 HRB

Same in both: Elastic (Young's) Modulus 70.3 GPa10.2 Msi · Shear Modulus 26.4 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.66 g/cm³0.1 lb/in³ · Melting Point (Solidus) 593°C1,099 °F · Liquidus Temperature 643°C1,189 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

125 W/m·K72.2 BTU/hr·ft·°F
127 W/m·K73.4 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.9 µm/m·K13.3 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Max Service Temperature (continuous) 65°C149 °F · Min Service Temperature -270°C-454 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

32 % IACS
32.3 % IACS

Same in both: Electrical Resistivity 5.4×10⁻⁸ Ω·m2.13 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

86 / 100
85 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.87 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
42 / 100

Machinability Rating (AISI 1212 = 100 %)

28%
30%

Formability (cold)

70 / 100
78 / 100

Same in both: Weldability 92 / 100 · Brazeability / Solderability 20 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5654

5654-AW vs 5654-H32 — frequently asked

Is 5654-H32 stronger than 5654-AW?

Yes. 5654-H32 has a typical yield strength of 205 MPa (29.7 ksi) against 105 MPa (15.2 ksi) for 5654-AW — about 95% more. Tensile strength is 270 MPa (39.2 ksi) vs 215 MPa (31.2 ksi).

Which condition does FabDigit quote by default, AW or H32?

O is the default 5654 condition in the FabDigit quote flow (neither AW nor H32). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 5654-AW or 5654-H32?

5654-H32, by a small margin. Both rate fair for machinability — 42/100 against 35/100 for 5654-AW.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5654-AW and 5654-H32 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.