Aluminum 5456-H112 vs 5456-H32

Aluminum · 5456 temper comparison

5456-H112 and 5456-H32 are two conditions of the same aluminum grade, 5456: H112 (strain hardened from hot working only) versus H32 (strain hardened and stabilized, quarter hard). The chemistry is identical, so every difference below comes from the condition. 5456-H32 is the stronger of the two: yield strength 255 MPa (37 ksi) against 165 MPa (23.9 ksi) for 5456-H112, about 55% more; tensile strength follows at 352 MPa (51.1 ksi) vs 310 MPa (45 ksi). In exchange, 5456-H112 is the more ductile: elongation 18% versus 16% for 5456-H32, and 5456-H32 is harder (90 HB vs 73 HB).

5456-H112Choose it when the part is bent, formed or impact-loaded.

5456-H32Choose it when strength drives the design.

5456-H112 vs 5456-H32: properties

5456-H1125456-H32

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Shear Modulus

26.4 GPa3.8 Msi
26.5 GPa3.8 Msi

Bulk Modulus

69 GPa10 Msi
70 GPa10.2 Msi

Tensile Strength (Ultimate)

310 MPa45 ksi
352 MPa51.1 ksi

Yield Strength (0.2% offset)

165 MPa23.9 ksi
255 MPa37 ksi

Elongation at Break

18%
16%

Compressive Strength

170 MPa24.7 ksi
260 MPa37.7 ksi

Shear Strength

190 MPa27.6 ksi
205 MPa29.7 ksi

Fatigue Strength (Endurance Limit)

135 MPa19.6 ksi
150 MPa21.8 ksi

Fracture Toughness (K_IC)

43 MPa·√m39.1 ksi·√in
35 MPa·√m31.9 ksi·√in

Hardness, Brinell

73 HB
90 HB

Hardness, Vickers

77 HV
95 HV

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.66 g/cm³0.1 lb/in³ · Melting Point (Solidus) 568°C1,054 °F · Liquidus Temperature 638°C1,180 °F

Thermal

How each material carries heat and how hot it can run.

Latent Heat of Fusion

390 J/g168 BTU/lb
395 J/g170 BTU/lb

Same in both: Thermal Conductivity 117 W/m·K67.6 BTU/hr·ft·°F · Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.9 µm/m·K13.3 µin/in·°F · Max Service Temperature (continuous) 65°C149 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 29 % IACS · Electrical Resistivity 5.9×10⁻⁸ Ω·m2.32 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

74 / 100
78 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.87 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
30%

Weldability

90 / 100
85 / 100

Formability (cold)

60 / 100
55 / 100

Brazeability / Solderability

15 / 100
20 / 100

Same in both: Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Water

1,200 L/kg144 gal/lb
1,100 L/kg132 gal/lb

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5456

5456-H112 vs 5456-H32 — frequently asked

Is 5456-H32 stronger than 5456-H112?

Yes. 5456-H32 has a typical yield strength of 255 MPa (37 ksi) against 165 MPa (23.9 ksi) for 5456-H112 — about 55% more. Tensile strength is 352 MPa (51.1 ksi) vs 310 MPa (45 ksi).

Which condition does FabDigit quote by default, H112 or H32?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 5456-H112 or 5456-H32?

5456-H32, by a small margin. Both rate fair for machinability — 50/100 against 45/100 for 5456-H112; for welding the order is 5456-H112 first (excellent, 90/100) then 5456-H32 (excellent, 85/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5456-H112 and 5456-H32 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.