FabDigitFabDigit

Aluminum 5352-H32 vs 5352-H34

Aluminum · 5352 temper comparison

5352-H32 and 5352-H34 are two conditions of the same aluminum grade, 5352: H32 (strain hardened and stabilized, quarter hard) versus H34 (strain hardened and stabilized, half hard). The chemistry is identical, so every difference below comes from the condition. 5352-H34 is the stronger of the two: yield strength 215 MPa (31.2 ksi) against 195 MPa (28.3 ksi) for 5352-H32, about 10% more; tensile strength follows at 260 MPa (37.7 ksi) vs 230 MPa (33.4 ksi). In exchange, 5352-H32 is the more ductile: elongation 12% versus 10% for 5352-H34, and 5352-H34 is harder (68 HB vs 60 HB). 5352-H34 runs hotter in service (150°C vs 120°C continuous).

5352-H32Choose it when the part is bent, formed or impact-loaded.

5352-H34Choose it when strength drives the design, or when the part sees heat.

5352-H32 vs 5352-H34: properties

5352-H325352-H34

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

230 MPa33.4 ksi
260 MPa37.7 ksi

Yield Strength (0.2% offset)

195 MPa28.3 ksi
215 MPa31.2 ksi

Elongation at Break

12%
10%

Shear Strength

140 MPa20.3 ksi
145 MPa21 ksi

Fatigue Strength (Endurance Limit)

115 MPa16.7 ksi
125 MPa18.1 ksi

Hardness, Brinell

60 HB
68 HB

Same in both: Elastic (Young's) Modulus 70.3 GPa10.2 Msi · Shear Modulus 25.9 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.68 g/cm³0.1 lb/in³ · Melting Point (Solidus) 607°C1,125 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

120°C248 °F
150°C302 °F

Same in both: Thermal Conductivity 138 W/m·K79.7 BTU/hr·ft·°F · Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.8 µm/m·K13.2 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 35 % IACS · Electrical Resistivity 4.9×10⁻⁸ Ω·m1.93 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

75 / 100
77 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.85 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

42 / 100
45 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
43%

Formability (cold)

70 / 100
58 / 100

Same in both: Weldability 90 / 100 · Brazeability / Solderability 25 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5352

5352-H32 vs 5352-H34 — frequently asked

Is 5352-H34 stronger than 5352-H32?

Yes. 5352-H34 has a typical yield strength of 215 MPa (31.2 ksi) against 195 MPa (28.3 ksi) for 5352-H32 — about 10% more. Tensile strength is 260 MPa (37.7 ksi) vs 230 MPa (33.4 ksi).

Which condition does FabDigit quote by default, H32 or H34?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

When should I choose 5352-H32 over 5352-H34?

Pick 5352-H32 when the part is bent, formed or impact-loaded. Pick 5352-H34 when strength drives the design, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5352-H32 and 5352-H34 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.