FabDigitFabDigit

Aluminum 5352-H14 vs 5352-O

Aluminum · 5352 temper comparison

5352-H14 and 5352-O are two conditions of the same aluminum grade, 5352: H14 (strain hardened, half hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 5352-H14 is the stronger of the two: yield strength 215 MPa (31.2 ksi) against 90 MPa (13.1 ksi) for 5352-O, about 139% more; tensile strength follows at 260 MPa (37.7 ksi) vs 195 MPa (28.3 ksi). In exchange, 5352-O is the more ductile: elongation 25% versus 10% for 5352-H14, and 5352-H14 is harder (68 HB vs 47 HB). On the shop floor, 5352-H14 machines more easily (fair vs poor).

5352-H14Choose it when strength drives the design, or when the part is machined in volume.

5352-OChoose it when the part is bent, formed or impact-loaded.

5352-H14 vs 5352-O: properties

5352-H145352-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

260 MPa37.7 ksi
195 MPa28.3 ksi

Yield Strength (0.2% offset)

215 MPa31.2 ksi
90 MPa13.1 ksi

Elongation at Break

10%
25%

Shear Strength

145 MPa21 ksi
125 MPa18.1 ksi

Fatigue Strength (Endurance Limit)

125 MPa18.1 ksi
110 MPa16 ksi

Hardness, Brinell

68 HB
47 HB

Same in both: Elastic (Young's) Modulus 70.3 GPa10.2 Msi · Shear Modulus 25.9 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.68 g/cm³0.1 lb/in³ · Melting Point (Solidus) 607°C1,125 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

138 W/m·K79.7 BTU/hr·ft·°F
144 W/m·K83.2 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.8 µm/m·K13.2 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Max Service Temperature (continuous) 120°C248 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

35 % IACS
36 % IACS

Same in both: Electrical Resistivity 4.9×10⁻⁸ Ω·m1.93 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.85 V · Corrosion Resistance 75 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
32 / 100

Machinability Rating (AISI 1212 = 100 %)

43%
30%

Formability (cold)

60 / 100
90 / 100

Same in both: Weldability 90 / 100 · Brazeability / Solderability 25 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5352

5352-H14 vs 5352-O — frequently asked

Is 5352-H14 stronger than 5352-O?

Yes. 5352-H14 has a typical yield strength of 215 MPa (31.2 ksi) against 90 MPa (13.1 ksi) for 5352-O — about 139% more. Tensile strength is 260 MPa (37.7 ksi) vs 195 MPa (28.3 ksi).

Which condition does FabDigit quote by default, H14 or O?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 5352-H14 or 5352-O?

5352-H14. Its machinability rates fair (45/100) against poor (32/100) for 5352-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5352-H14 and 5352-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.