FabDigitFabDigit

Aluminum 5352-H112 vs 5352-H14

Aluminum · 5352 temper comparison

5352-H112 and 5352-H14 are two conditions of the same aluminum grade, 5352: H112 (strain hardened from hot working only) versus H14 (strain hardened, half hard). The chemistry is identical, so every difference below comes from the condition. 5352-H14 is the stronger of the two: yield strength 215 MPa (31.2 ksi) against 110 MPa (16 ksi) for 5352-H112, about 95% more; tensile strength follows at 260 MPa (37.7 ksi) vs 200 MPa (29 ksi). In exchange, 5352-H112 is the more ductile: elongation 18% versus 10% for 5352-H14, and 5352-H14 is harder (68 HB vs 50 HB). 5352-H112 runs hotter in service (150°C vs 120°C continuous). On the shop floor, 5352-H14 machines more easily (45 vs 35 out of 100).

5352-H112Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5352-H14Choose it when strength drives the design, or when the part is machined in volume.

5352-H112 vs 5352-H14: properties

5352-H1125352-H14

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

200 MPa29 ksi
260 MPa37.7 ksi

Yield Strength (0.2% offset)

110 MPa16 ksi
215 MPa31.2 ksi

Elongation at Break

18%
10%

Shear Strength

125 MPa18.1 ksi
145 MPa21 ksi

Fatigue Strength (Endurance Limit)

95 MPa13.8 ksi
125 MPa18.1 ksi

Hardness, Brinell

50 HB
68 HB

Same in both: Elastic (Young's) Modulus 70.3 GPa10.2 Msi · Shear Modulus 25.9 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.68 g/cm³0.1 lb/in³ · Melting Point (Solidus) 607°C1,125 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

140 W/m·K80.9 BTU/hr·ft·°F
138 W/m·K79.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
120°C248 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.8 µm/m·K13.2 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 35 % IACS · Electrical Resistivity 4.9×10⁻⁸ Ω·m1.93 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

77 / 100
75 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.85 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
45 / 100

Machinability Rating (AISI 1212 = 100 %)

32%
43%

Weldability

92 / 100
90 / 100

Formability (cold)

80 / 100
60 / 100

Same in both: Brazeability / Solderability 25 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5352

5352-H112 vs 5352-H14 — frequently asked

Is 5352-H14 stronger than 5352-H112?

Yes. 5352-H14 has a typical yield strength of 215 MPa (31.2 ksi) against 110 MPa (16 ksi) for 5352-H112 — about 95% more. Tensile strength is 260 MPa (37.7 ksi) vs 200 MPa (29 ksi).

Which condition does FabDigit quote by default, H112 or H14?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 5352-H112 or 5352-H14?

5352-H14, by a small margin. Both rate fair for machinability — 45/100 against 35/100 for 5352-H112.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5352-H112 and 5352-H14 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.