FabDigitFabDigit

Aluminum 5254-H112 vs 5254-H32

Aluminum · 5254 temper comparison

5254-H112 and 5254-H32 are two conditions of the same aluminum grade, 5254: H112 (strain hardened from hot working only) versus H32 (strain hardened and stabilized, quarter hard). The chemistry is identical, so every difference below comes from the condition. 5254-H32 is the stronger of the two: yield strength 205 MPa (29.7 ksi) against 115 MPa (16.7 ksi) for 5254-H112, about 78% more; tensile strength follows at 270 MPa (39.2 ksi) vs 240 MPa (34.8 ksi). In exchange, 5254-H112 is the more ductile: elongation 25% versus 15% for 5254-H32, and 5254-H32 is harder (67 HB vs 63 HB).

5254-H112Choose it when the part is bent, formed or impact-loaded.

5254-H32Choose it when strength drives the design.

5254-H112 vs 5254-H32: properties

5254-H1125254-H32

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

240 MPa34.8 ksi
270 MPa39.2 ksi

Yield Strength (0.2% offset)

115 MPa16.7 ksi
205 MPa29.7 ksi

Elongation at Break

25%
15%

Shear Strength

155 MPa22.5 ksi
150 MPa21.8 ksi

Fatigue Strength (Endurance Limit)

115 MPa16.7 ksi
125 MPa18.1 ksi

Hardness, Brinell

63 HB
67 HB

Same in both: Elastic (Young's) Modulus 70.3 GPa10.2 Msi · Shear Modulus 26.4 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33 · Hardness, Vickers 72 HV

Physical

Density and transition temperatures.

Same in both: Density 2.66 g/cm³0.1 lb/in³ · Melting Point (Solidus) 593°C1,099 °F · Liquidus Temperature 643°C1,189 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

128 W/m·K74 BTU/hr·ft·°F
126 W/m·K72.8 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.9 µm/m·K13.3 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Max Service Temperature (continuous) 65°C149 °F · Min Service Temperature -270°C-454 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

33 % IACS
32 % IACS

Same in both: Electrical Resistivity 5.4×10⁻⁸ Ω·m2.13 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

81 / 100
80 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.86 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
45 / 100

Formability (cold)

75 / 100
60 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 88 / 100 · Castability 25 / 100 · Brazeability / Solderability 20 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5254

5254-H112 vs 5254-H32 — frequently asked

Is 5254-H32 stronger than 5254-H112?

Yes. 5254-H32 has a typical yield strength of 205 MPa (29.7 ksi) against 115 MPa (16.7 ksi) for 5254-H112 — about 78% more. Tensile strength is 270 MPa (39.2 ksi) vs 240 MPa (34.8 ksi).

Which condition does FabDigit quote by default, H112 or H32?

H32 is the default 5254 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 5254-H112 or 5254-H32?

5254-H32, by a small margin. Both rate fair for machinability — 45/100 against 40/100 for 5254-H112.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5254-H112 and 5254-H32 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.