5254-H112 and 5254-H14 are two conditions of the same aluminum grade, 5254: H112 (strain hardened from hot working only) versus H14 (strain hardened, half hard). The chemistry is identical, so every difference below comes from the condition. 5254-H14 is the stronger of the two: yield strength 240 MPa (34.8 ksi) against 115 MPa (16.7 ksi) for 5254-H112, about 109% more; tensile strength follows at 290 MPa (42.1 ksi) vs 240 MPa (34.8 ksi). In exchange, 5254-H112 is the more ductile: elongation 25% versus 10% for 5254-H14, and 5254-H14 is harder (73 HB vs 63 HB).

5254-H112Choose it when the part is bent, formed or impact-loaded.

5254-H14Choose it when strength drives the design.

5254-H112 vs 5254-H14: properties

5254-H1125254-H14

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

240 MPa34.8 ksi
290 MPa42.1 ksi

Yield Strength (0.2% offset)

115 MPa16.7 ksi
240 MPa34.8 ksi

Elongation at Break

25%
10%

Shear Strength

155 MPa22.5 ksi
165 MPa23.9 ksi

Fatigue Strength (Endurance Limit)

115 MPa16.7 ksi
130 MPa18.9 ksi

Hardness, Brinell

63 HB
73 HB

Hardness, Vickers

72 HV
78 HV

Same in both: Elastic (Young's) Modulus 70.3 GPa10.2 Msi · Shear Modulus 26.4 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.66 g/cm³0.1 lb/in³ · Melting Point (Solidus) 593°C1,099 °F · Liquidus Temperature 643°C1,189 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

128 W/m·K74 BTU/hr·ft·°F
126 W/m·K72.8 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.9 µm/m·K13.3 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Max Service Temperature (continuous) 65°C149 °F · Min Service Temperature -270°C-454 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

33 % IACS
32 % IACS

Same in both: Electrical Resistivity 5.4×10⁻⁸ Ω·m2.13 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

81 / 100
77 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.86 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
48 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
32%

Formability (cold)

75 / 100
50 / 100

Same in both: Weldability 88 / 100 · Castability 25 / 100 · Brazeability / Solderability 20 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5254

5254-H112 vs 5254-H14 — frequently asked

Is 5254-H14 stronger than 5254-H112?

Yes. 5254-H14 has a typical yield strength of 240 MPa (34.8 ksi) against 115 MPa (16.7 ksi) for 5254-H112 — about 109% more. Tensile strength is 290 MPa (42.1 ksi) vs 240 MPa (34.8 ksi).

Which condition does FabDigit quote by default, H112 or H14?

H32 is the default 5254 condition in the FabDigit quote flow (neither H112 nor H14). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 5254-H112 or 5254-H14?

5254-H14, by a small margin. Both rate fair for machinability — 48/100 against 40/100 for 5254-H112.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5254-H112 and 5254-H14 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.