5154A-H112 and 5154A-H32 are two conditions of the same aluminum grade, 5154A: H112 (strain hardened from hot working only) versus H32 (strain hardened and stabilized, quarter hard). The chemistry is identical, so every difference below comes from the condition. 5154A-H32 is the stronger of the two: yield strength 205 MPa (29.7 ksi) against 120 MPa (17.4 ksi) for 5154A-H112, about 71% more; tensile strength follows at 270 MPa (39.2 ksi) vs 240 MPa (34.8 ksi). In exchange, 5154A-H112 is the more ductile: elongation 20% versus 13% for 5154A-H32, and 5154A-H32 is harder (67 HB vs 63 HB). 5154A-H112 runs hotter in service (90°C vs 70°C continuous).

5154A-H112Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5154A-H32Choose it when strength drives the design.

5154A-H112 vs 5154A-H32: properties

5154A-H1125154A-H32

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

240 MPa34.8 ksi
270 MPa39.2 ksi

Yield Strength (0.2% offset)

120 MPa17.4 ksi
205 MPa29.7 ksi

Elongation at Break

20%
13%

Shear Strength

152 MPa22 ksi
160 MPa23.2 ksi

Fatigue Strength (Endurance Limit)

117 MPa17 ksi
125 MPa18.1 ksi

Hardness, Brinell

63 HB
67 HB

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.4 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33 · Compressive Strength 195 MPa28.3 ksi · Fracture Toughness (K_IC) 32 MPa·√m29.1 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 2.66 g/cm³0.1 lb/in³ · Melting Point (Solidus) 590°C1,094 °F · Liquidus Temperature 643°C1,189 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

90°C194 °F
70°C158 °F

Same in both: Thermal Conductivity 127 W/m·K73.4 BTU/hr·ft·°F · Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.7 µm/m·K13.2 µin/in·°F · Latent Heat of Fusion 393 J/g169 BTU/lb · Min Service Temperature -270°C-454 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 32 % IACS · Electrical Resistivity 5.4×10⁻⁸ Ω·m2.13 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

78 / 100
80 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.86 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
45 / 100

Weldability

91 / 100
90 / 100

Formability (cold)

78 / 100
66 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 35% · Castability 25 / 100 · Brazeability / Solderability 20 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5154A

5154A-H112 vs 5154A-H32 — frequently asked

Is 5154A-H32 stronger than 5154A-H112?

Yes. 5154A-H32 has a typical yield strength of 205 MPa (29.7 ksi) against 120 MPa (17.4 ksi) for 5154A-H112 — about 71% more. Tensile strength is 270 MPa (39.2 ksi) vs 240 MPa (34.8 ksi).

Which condition does FabDigit quote by default, H112 or H32?

H22 is the default 5154A condition in the FabDigit quote flow (neither H112 nor H32). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 5154A-H112 or 5154A-H32?

5154A-H32, by a small margin. Both rate fair for machinability — 45/100 against 40/100 for 5154A-H112.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5154A-H112 and 5154A-H32 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.