FabDigitFabDigit

Aluminum 5019-H111 vs 5019-H32

Aluminum · 5019 temper comparison

5019-H111 and 5019-H32 are two conditions of the same aluminum grade, 5019: H111 (slightly strain hardened) versus H32 (strain hardened and stabilized, quarter hard). The chemistry is identical, so every difference below comes from the condition. 5019-H32 is the stronger of the two: yield strength 235 MPa (34.1 ksi) against 145 MPa (21 ksi) for 5019-H111, about 62% more; tensile strength follows at 330 MPa (47.9 ksi) vs 290 MPa (42.1 ksi). In exchange, 5019-H111 is the more ductile: elongation 21% versus 12% for 5019-H32, and 5019-H32 is harder (87 HB vs 72 HB).

5019-H111Choose it when the part is bent, formed or impact-loaded.

5019-H32Choose it when strength drives the design.

5019-H111 vs 5019-H32: properties

5019-H1115019-H32

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

290 MPa42.1 ksi
330 MPa47.9 ksi

Yield Strength (0.2% offset)

145 MPa21 ksi
235 MPa34.1 ksi

Elongation at Break

21%
12%

Shear Strength

175 MPa25.4 ksi
190 MPa27.6 ksi

Fatigue Strength (Endurance Limit)

125 MPa18.1 ksi
145 MPa21 ksi

Fracture Toughness (K_IC)

38 MPa·√m34.6 ksi·√in
32 MPa·√m29.1 ksi·√in

Charpy V-Notch Impact (RT)

38 J28 ft·lbf
30 J22.1 ft·lbf

Hardness, Brinell

72 HB
87 HB

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.4 GPa3.8 Msi · Bulk Modulus 68 GPa9.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.64 g/cm³0.1 lb/in³ · Melting Point (Solidus) 570°C1,058 °F · Liquidus Temperature 630°C1,166 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

115 W/m·K66.4 BTU/hr·ft·°F
113 W/m·K65.3 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 24.2 µm/m·K13.4 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Max Service Temperature (continuous) 65°C149 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

29 % IACS
28 % IACS

Electrical Resistivity

5.95×10⁻⁸ Ω·m2.34 µΩ·in
6.2×10⁻⁸ Ω·m2.44 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

80 / 100
78 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.87 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
45 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
35%

Weldability

85 / 100
83 / 100

Formability (cold)

80 / 100
55 / 100

Same in both: Castability 25 / 100 · Brazeability / Solderability 20 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5019

5019-H111 vs 5019-H32 — frequently asked

Is 5019-H32 stronger than 5019-H111?

Yes. 5019-H32 has a typical yield strength of 235 MPa (34.1 ksi) against 145 MPa (21 ksi) for 5019-H111 — about 62% more. Tensile strength is 330 MPa (47.9 ksi) vs 290 MPa (42.1 ksi).

Which condition does FabDigit quote by default, H111 or H32?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 5019-H111 or 5019-H32?

5019-H32, by a small margin. Both rate fair for machinability — 45/100 against 40/100 for 5019-H111.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5019-H111 and 5019-H32 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.