FabDigitFabDigit

Aluminum 344.0-T5 vs 344.0-T6

Aluminum · 344.0 temper comparison

344.0-T5 and 344.0-T6 are two conditions of the same aluminum grade, 344.0: T5 (cooled from hot working and artificially aged) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. 344.0-T6 is the stronger of the two: yield strength 210 MPa (30.5 ksi) against 170 MPa (24.7 ksi) for 344.0-T5, about 24% more; tensile strength follows at 285 MPa (41.3 ksi) vs 235 MPa (34.1 ksi). 344.0-T6 is harder — 105 HB against 95 HB for 344.0-T5 — which matters for wear surfaces and threads. 344.0-T5 conducts electricity better (30 % IACS vs 27 % IACS).

344.0-T6Choose it when strength drives the design, or when surface hardness matters.

344.0-T5 vs 344.0-T6: properties

344.0-T5344.0-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

235 MPa34.1 ksi
285 MPa41.3 ksi

Yield Strength (0.2% offset)

170 MPa24.7 ksi
210 MPa30.5 ksi

Shear Strength

180 MPa26.1 ksi
210 MPa30.5 ksi

Fatigue Strength (Endurance Limit)

95 MPa13.8 ksi
100 MPa14.5 ksi

Hardness, Brinell

95 HB
105 HB

Same in both: Elastic (Young's) Modulus 74 GPa10.7 Msi · Shear Modulus 28 GPa4.1 Msi · Bulk Modulus 72 GPa10.4 Msi · Poisson's Ratio 0.33 · Elongation at Break 1.5% · Compressive Strength 130 MPa18.9 ksi · Fracture Toughness (K_IC) 17 MPa·√m15.5 ksi·√in · Charpy V-Notch Impact (RT) 4 J3 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 2.75 g/cm³0.1 lb/in³ · Melting Point (Solidus) 521°C970 °F · Liquidus Temperature 582°C1,080 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

115 W/m·K66.4 BTU/hr·ft·°F
105 W/m·K60.7 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21 µm/m·K11.7 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Max Service Temperature (continuous) 175°C347 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

30 % IACS
27 % IACS

Same in both: Electrical Resistivity 6.2×10⁻⁸ Ω·m2.44 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 40 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
60 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 70% · Weldability 40 / 100 · Formability (cold) 5 / 100 · Castability 88 / 100 · Brazeability / Solderability 20 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 155 MJ/kg66,638 BTU/lb · Embodied Carbon (primary production) 9.5 kg CO₂/kg · Embodied Water 900 L/kg108 gal/lb · Typical Recycled Content 75%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale344.0

344.0-T5 vs 344.0-T6 — frequently asked

Is 344.0-T6 stronger than 344.0-T5?

Yes. 344.0-T6 has a typical yield strength of 210 MPa (30.5 ksi) against 170 MPa (24.7 ksi) for 344.0-T5 — about 24% more. Tensile strength is 285 MPa (41.3 ksi) vs 235 MPa (34.1 ksi).

Which condition does FabDigit quote by default, T5 or T6?

F is the default 344.0 condition in the FabDigit quote flow (neither T5 nor T6). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 344.0-T5 over 344.0-T6?

Pick 344.0-T6 when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 344.0-T5 and 344.0-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.