FabDigitFabDigit

Aluminum 344.0-F vs 344.0-T6

Aluminum · 344.0 temper comparison

344.0-F and 344.0-T6 are two conditions of the same aluminum grade, 344.0: F (as fabricated) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. 344.0-T6 is the stronger of the two: yield strength 210 MPa (30.5 ksi) against 125 MPa (18.1 ksi) for 344.0-F, about 68% more; tensile strength follows at 285 MPa (41.3 ksi) vs 220 MPa (31.9 ksi). In exchange, 344.0-F is the more ductile: elongation 2% versus 1.5% for 344.0-T6, and 344.0-T6 is harder (105 HB vs 85 HB). 344.0-T6 runs hotter in service (175°C vs 150°C continuous).

344.0-FChoose it when the part is bent, formed or impact-loaded.

344.0-T6Choose it when strength drives the design, or when the part sees heat.

344.0-F vs 344.0-T6: properties

344.0-F344.0-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

220 MPa31.9 ksi
285 MPa41.3 ksi

Yield Strength (0.2% offset)

125 MPa18.1 ksi
210 MPa30.5 ksi

Elongation at Break

2%
1.5%

Shear Strength

165 MPa23.9 ksi
210 MPa30.5 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
100 MPa14.5 ksi

Hardness, Brinell

85 HB
105 HB

Same in both: Elastic (Young's) Modulus 74 GPa10.7 Msi · Shear Modulus 28 GPa4.1 Msi · Bulk Modulus 72 GPa10.4 Msi · Poisson's Ratio 0.33 · Compressive Strength 130 MPa18.9 ksi · Fracture Toughness (K_IC) 17 MPa·√m15.5 ksi·√in · Charpy V-Notch Impact (RT) 4 J3 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 2.75 g/cm³0.1 lb/in³ · Melting Point (Solidus) 521°C970 °F · Liquidus Temperature 582°C1,080 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

110 W/m·K63.6 BTU/hr·ft·°F
105 W/m·K60.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
175°C347 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21 µm/m·K11.7 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

28 % IACS
27 % IACS

Same in both: Electrical Resistivity 6.2×10⁻⁸ Ω·m2.44 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 40 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
60 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 70% · Weldability 40 / 100 · Formability (cold) 5 / 100 · Castability 88 / 100 · Brazeability / Solderability 20 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 155 MJ/kg66,638 BTU/lb · Embodied Carbon (primary production) 9.5 kg CO₂/kg · Embodied Water 900 L/kg108 gal/lb · Typical Recycled Content 75%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale344.0

344.0-F vs 344.0-T6 — frequently asked

Is 344.0-T6 stronger than 344.0-F?

Yes. 344.0-T6 has a typical yield strength of 210 MPa (30.5 ksi) against 125 MPa (18.1 ksi) for 344.0-F — about 68% more. Tensile strength is 285 MPa (41.3 ksi) vs 220 MPa (31.9 ksi).

Which condition does FabDigit quote by default, F or T6?

F is the default 344.0 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 344.0-F or 344.0-T6?

344.0-T6, by a small margin. Both rate good for machinability — 60/100 against 55/100 for 344.0-F.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 344.0-F and 344.0-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.