332.0-T5 and 332.0-T7 are two conditions of the same aluminum grade, 332.0: T5 (cooled from hot working and artificially aged) versus T7 (solution heat treated and overaged (stabilized)). The chemistry is identical, so every difference below comes from the condition. 332.0-T5 is the stronger of the two: yield strength 193 MPa (28 ksi) against 170 MPa (24.7 ksi) for 332.0-T7, about 14% more; tensile strength follows at 248 MPa (36 ksi) vs 225 MPa (32.6 ksi). In exchange, 332.0-T7 is the more ductile: elongation 1.5% versus 1% for 332.0-T5, and 332.0-T5 is harder (105 HB vs 95 HB). 332.0-T7 conducts electricity better (29 % IACS vs 26 % IACS).

332.0-T5Choose it when strength drives the design.

332.0-T7Choose it when the part is bent, formed or impact-loaded.

332.0-T5 vs 332.0-T7: properties

332.0-T5332.0-T7

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

248 MPa36 ksi
225 MPa32.6 ksi

Yield Strength (0.2% offset)

193 MPa28 ksi
170 MPa24.7 ksi

Elongation at Break

1%
1.5%

Compressive Strength

200 MPa29 ksi
180 MPa26.1 ksi

Shear Strength

193 MPa28 ksi
180 MPa26.1 ksi

Fatigue Strength (Endurance Limit)

62 MPa9 ksi
58 MPa8.4 ksi

Fracture Toughness (K_IC)

15 MPa·√m13.7 ksi·√in
17 MPa·√m15.5 ksi·√in

Hardness, Brinell

105 HB
95 HB

Same in both: Elastic (Young's) Modulus 76 GPa11 Msi · Shear Modulus 28 GPa4.1 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.76 g/cm³0.1 lb/in³ · Melting Point (Solidus) 521°C970 °F · Liquidus Temperature 582°C1,080 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

104 W/m·K60.1 BTU/hr·ft·°F
112 W/m·K64.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

250°C482 °F
260°C500 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.6 µm/m·K11.4 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -195°C-319 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

26 % IACS
29 % IACS

Electrical Resistivity

6.6×10⁻⁸ Ω·m2.6 µΩ·in
5.9×10⁻⁸ Ω·m2.32 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

35 / 100
37 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.79 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
58 / 100

Weldability

25 / 100
26 / 100

Formability (cold)

5 / 100
6 / 100

Same in both: Castability 85 / 100 · Brazeability / Solderability 15 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 45 MJ/kg19,347 BTU/lb · Embodied Carbon (primary production) 3.5 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 85%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale332.0

332.0-T5 vs 332.0-T7 — frequently asked

Is 332.0-T5 stronger than 332.0-T7?

Yes. 332.0-T5 has a typical yield strength of 193 MPa (28 ksi) against 170 MPa (24.7 ksi) for 332.0-T7 — about 14% more. Tensile strength is 248 MPa (36 ksi) vs 225 MPa (32.6 ksi).

Which condition does FabDigit quote by default, T5 or T7?

T5 is the default 332.0 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 332.0-T5 over 332.0-T7?

Pick 332.0-T5 when strength drives the design. Pick 332.0-T7 when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 332.0-T5 and 332.0-T7 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.