FabDigitFabDigit

Aluminum 332.0-F vs 332.0-T5

Aluminum · 332.0 temper comparison

332.0-F and 332.0-T5 are two conditions of the same aluminum grade, 332.0: F (as fabricated) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. 332.0-T5 is the stronger of the two: yield strength 193 MPa (28 ksi) against 140 MPa (20.3 ksi) for 332.0-F, about 38% more; tensile strength follows at 248 MPa (36 ksi) vs 214 MPa (31 ksi). In exchange, 332.0-F is the more ductile: elongation 1.5% versus 1% for 332.0-T5, and 332.0-T5 is harder (105 HB vs 90 HB). 332.0-T5 runs hotter in service (250°C vs 200°C continuous).

332.0-FChoose it when the part is bent, formed or impact-loaded.

332.0-T5Choose it when strength drives the design, or when the part sees heat.

332.0-F vs 332.0-T5: properties

332.0-F332.0-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

214 MPa31 ksi
248 MPa36 ksi

Yield Strength (0.2% offset)

140 MPa20.3 ksi
193 MPa28 ksi

Elongation at Break

1.5%
1%

Shear Strength

170 MPa24.7 ksi
193 MPa28 ksi

Fatigue Strength (Endurance Limit)

55 MPa8 ksi
62 MPa9 ksi

Hardness, Brinell

90 HB
105 HB

Same in both: Elastic (Young's) Modulus 76 GPa11 Msi · Shear Modulus 28 GPa4.1 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33 · Compressive Strength 200 MPa29 ksi · Fracture Toughness (K_IC) 15 MPa·√m13.7 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 2.76 g/cm³0.1 lb/in³ · Melting Point (Solidus) 521°C970 °F · Liquidus Temperature 582°C1,080 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

110 W/m·K63.6 BTU/hr·ft·°F
104 W/m·K60.1 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
250°C482 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.6 µm/m·K11.4 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -195°C-319 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

28 % IACS
26 % IACS

Same in both: Electrical Resistivity 6.6×10⁻⁸ Ω·m2.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.79 V · Corrosion Resistance 35 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
55 / 100

Same in both: Weldability 25 / 100 · Formability (cold) 5 / 100 · Castability 85 / 100 · Brazeability / Solderability 15 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 45 MJ/kg19,347 BTU/lb · Embodied Carbon (primary production) 3.5 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 85%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale332.0

332.0-F vs 332.0-T5 — frequently asked

Is 332.0-T5 stronger than 332.0-F?

Yes. 332.0-T5 has a typical yield strength of 193 MPa (28 ksi) against 140 MPa (20.3 ksi) for 332.0-F — about 38% more. Tensile strength is 248 MPa (36 ksi) vs 214 MPa (31 ksi).

Which condition does FabDigit quote by default, F or T5?

T5 is the default 332.0 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 332.0-F over 332.0-T5?

Pick 332.0-F when the part is bent, formed or impact-loaded. Pick 332.0-T5 when strength drives the design, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 332.0-F and 332.0-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.