FabDigitFabDigit

Aluminum 3105-H111 vs 3105-H19

Aluminum · 3105 temper comparison

3105-H111 and 3105-H19 are two conditions of the same aluminum grade, 3105: H111 (slightly strain hardened) versus H19 (strain hardened, extra hard). The chemistry is identical, so every difference below comes from the condition. 3105-H19 is the stronger of the two: yield strength 215 MPa (31.2 ksi) against 55 MPa (7.98 ksi) for 3105-H111, about 3.9 times as much; tensile strength follows at 230 MPa (33.4 ksi) vs 125 MPa (18.1 ksi). In exchange, 3105-H111 is the more ductile: elongation 22% versus 1.5% for 3105-H19, and 3105-H19 is harder (63 HB vs 33 HB). 3105-H111 runs hotter in service (175°C vs 100°C continuous). On the shop floor, 3105-H19 machines more easily (good vs fair).

3105-H111Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

3105-H19Choose it when strength drives the design, or when the part is machined in volume.

3105-H111 vs 3105-H19: properties

3105-H1113105-H19

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

125 MPa18.1 ksi
230 MPa33.4 ksi

Yield Strength (0.2% offset)

55 MPa8 ksi
215 MPa31.2 ksi

Elongation at Break

22%
1.5%

Shear Strength

80 MPa11.6 ksi
125 MPa18.1 ksi

Fatigue Strength (Endurance Limit)

48 MPa7 ksi
72 MPa10.4 ksi

Hardness, Brinell

33 HB
63 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.72 g/cm³0.1 lb/in³ · Melting Point (Solidus) 638°C1,180 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

173 W/m·K100 BTU/hr·ft·°F
172 W/m·K99.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

175°C347 °F
100°C212 °F

Same in both: Specific Heat Capacity 897 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 393 J/g169 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

42 % IACS
41 % IACS

Electrical Resistivity

4.1×10⁻⁸ Ω·m1.61 µΩ·in
4.2×10⁻⁸ Ω·m1.65 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

68 / 100
66 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
45%

Weldability

85 / 100
80 / 100

Formability (cold)

92 / 100
20 / 100

Brazeability / Solderability

60 / 100
55 / 100

Polishability

55 / 100
60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale3105

3105-H111 vs 3105-H19 — frequently asked

Is 3105-H19 stronger than 3105-H111?

Yes. 3105-H19 has a typical yield strength of 215 MPa (31.2 ksi) against 55 MPa (7.98 ksi) for 3105-H111 — about 3.9 times as much. Tensile strength is 230 MPa (33.4 ksi) vs 125 MPa (18.1 ksi).

Which condition does FabDigit quote by default, H111 or H19?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 3105-H111 or 3105-H19?

3105-H19. Its machinability rates good (55/100) against fair (35/100) for 3105-H111; for welding the order is 3105-H111 first (excellent, 85/100) then 3105-H19 (very good, 80/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 3105-H111 and 3105-H19 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.