FabDigitFabDigit

Aluminum 2618A-O vs 2618A-T651

Aluminum · 2618A temper comparison

2618A-O and 2618A-T651 are two conditions of the same aluminum grade, 2618A: O (annealed) versus T651 (T6, stress relieved by stretching). The chemistry is identical, so every difference below comes from the condition. 2618A-T651 is the stronger of the two: yield strength 378 MPa (54.8 ksi) against 130 MPa (18.9 ksi) for 2618A-O, about 191% more; tensile strength follows at 440 MPa (63.8 ksi) vs 240 MPa (34.8 ksi). In exchange, 2618A-O is the more ductile: elongation 18% versus 8% for 2618A-T651, and 2618A-T651 is harder (118 HB vs 65 HB). 2618A-O conducts electricity better (44 % IACS vs 39 % IACS). On the shop floor, 2618A-T651 machines more easily (very good vs fair).

2618A-OChoose it when the part is bent, formed or impact-loaded.

2618A-T651Choose it when strength drives the design, or when the part is machined in volume.

2618A-O vs 2618A-T651: properties

2618A-O2618A-T651

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

240 MPa34.8 ksi
440 MPa63.8 ksi

Yield Strength (0.2% offset)

130 MPa18.9 ksi
378 MPa54.8 ksi

Elongation at Break

18%
8%

Reduction in Area

30%
19%

Compressive Strength

135 MPa19.6 ksi
388 MPa56.3 ksi

Shear Strength

150 MPa21.8 ksi
260 MPa37.7 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
125 MPa18.1 ksi

Fracture Toughness (K_IC)

36 MPa·√m32.8 ksi·√in
28 MPa·√m25.5 ksi·√in

Charpy V-Notch Impact (RT)

18 J13.3 ft·lbf
8 J5.9 ft·lbf

Hardness, Brinell

65 HB
118 HB

Hardness, Vickers

70 HV
128 HV

Same in both: Elastic (Young's) Modulus 74 GPa10.7 Msi · Shear Modulus 27.5 GPa4 Msi · Bulk Modulus 72 GPa10.4 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.76 g/cm³0.1 lb/in³ · Melting Point (Solidus) 502°C936 °F · Liquidus Temperature 638°C1,180 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

160 W/m·K92.4 BTU/hr·ft·°F
146 W/m·K84.4 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 875 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.3 µm/m·K12.4 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

44 % IACS
39 % IACS

Electrical Resistivity

3.92×10⁻⁸ Ω·m1.54 µΩ·in
4.42×10⁻⁸ Ω·m1.74 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

36 / 100
32 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.72 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
70 / 100

Machinability Rating (AISI 1212 = 100 %)

32%
57%

Weldability

20 / 100
18 / 100

Formability (cold)

50 / 100
20 / 100

Same in both: Brazeability / Solderability 15 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 210 MJ/kg90,284 BTU/lb · Embodied Carbon (primary production) 14 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 12%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale2618A

2618A-O vs 2618A-T651 — frequently asked

Is 2618A-T651 stronger than 2618A-O?

Yes. 2618A-T651 has a typical yield strength of 378 MPa (54.8 ksi) against 130 MPa (18.9 ksi) for 2618A-O — about 191% more. Tensile strength is 440 MPa (63.8 ksi) vs 240 MPa (34.8 ksi).

Which condition does FabDigit quote by default, O or T651?

T851 is the default 2618A condition in the FabDigit quote flow (neither O nor T651). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 2618A-O or 2618A-T651?

2618A-T651. Its machinability rates very good (70/100) against fair (45/100) for 2618A-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 2618A-O and 2618A-T651 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.