FabDigitFabDigit

Aluminum 2319-H14 vs 2319-T6

Aluminum · 2319 temper comparison

2319-H14 and 2319-T6 are two conditions of the same aluminum grade, 2319: H14 (strain hardened, half hard) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. 2319-T6 is the stronger of the two: yield strength 300 MPa (43.5 ksi) against 200 MPa (29 ksi) for 2319-H14, about 50% more; tensile strength follows at 420 MPa (60.9 ksi) vs 260 MPa (37.7 ksi). 2319-T6 is harder — 118 HB against 78 HB for 2319-H14 — which matters for wear surfaces and threads. 2319-T6 runs hotter in service (175°C vs 150°C continuous) and 2319-H14 conducts heat better (165 W/m·K vs 120 W/m·K). On the shop floor, 2319-T6 forms better (good vs fair).

2319-T6Choose it when strength drives the design, or when surface hardness matters.

2319-H14 vs 2319-T6: properties

2319-H142319-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

260 MPa37.7 ksi
420 MPa60.9 ksi

Yield Strength (0.2% offset)

200 MPa29 ksi
300 MPa43.5 ksi

Shear Strength

150 MPa21.8 ksi
250 MPa36.3 ksi

Fatigue Strength (Endurance Limit)

85 MPa12.3 ksi
105 MPa15.2 ksi

Fracture Toughness (K_IC)

28 MPa·√m25.5 ksi·√in
32 MPa·√m29.1 ksi·√in

Hardness, Brinell

78 HB
118 HB

Same in both: Elastic (Young's) Modulus 73 GPa10.6 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33 · Elongation at Break 8%

Physical

Density and transition temperatures.

Same in both: Density 2.84 g/cm³0.1 lb/in³ · Melting Point (Solidus) 543°C1,009 °F · Liquidus Temperature 643°C1,189 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

165 W/m·K95.3 BTU/hr·ft·°F
120 W/m·K69.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
175°C347 °F

Same in both: Specific Heat Capacity 864 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.3 µm/m·K12.4 µin/in·°F · Latent Heat of Fusion 385 J/g166 BTU/lb · Min Service Temperature -253°C-423 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

42 % IACS
30 % IACS

Electrical Resistivity

4.1×10⁻⁸ Ω·m1.61 µΩ·in
3.9×10⁻⁸ Ω·m1.54 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

30 / 100
32 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.64 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
68 / 100

Formability (cold)

45 / 100
55 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 55% · Weldability 92 / 100 · Castability 60 / 100 · Brazeability / Solderability 20 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 10%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale2319

2319-H14 vs 2319-T6 — frequently asked

Is 2319-T6 stronger than 2319-H14?

Yes. 2319-T6 has a typical yield strength of 300 MPa (43.5 ksi) against 200 MPa (29 ksi) for 2319-H14 — about 50% more. Tensile strength is 420 MPa (60.9 ksi) vs 260 MPa (37.7 ksi).

Which condition does FabDigit quote by default, H14 or T6?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 2319-H14 or 2319-T6?

2319-T6, by a small margin. Both rate good for machinability — 68/100 against 62/100 for 2319-H14.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 2319-H14 and 2319-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.