FabDigitFabDigit

Aluminum 2199-O vs 2199-T3

Aluminum · 2199 temper comparison

2199-O and 2199-T3 are two conditions of the same aluminum grade, 2199: O (annealed) versus T3 (solution heat treated, cold worked and naturally aged). The chemistry is identical, so every difference below comes from the condition. 2199-T3 is the stronger of the two: yield strength 270 MPa (39.2 ksi) against 135 MPa (19.6 ksi) for 2199-O, about 100% more; tensile strength follows at 400 MPa (58 ksi) vs 250 MPa (36.3 ksi). In exchange, 2199-O is the more ductile: elongation 20% versus 18% for 2199-T3, and 2199-T3 is harder (110 HB vs 65 HB). 2199-O conducts heat better (120 W/m·K vs 82 W/m·K).

2199-OChoose it when the part is bent, formed or impact-loaded.

2199-T3Choose it when strength drives the design.

2199-O vs 2199-T3: properties

2199-O2199-T3

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

250 MPa36.3 ksi
400 MPa58 ksi

Yield Strength (0.2% offset)

135 MPa19.6 ksi
270 MPa39.2 ksi

Elongation at Break

20%
18%

Shear Strength

160 MPa23.2 ksi
245 MPa35.5 ksi

Fatigue Strength (Endurance Limit)

95 MPa13.8 ksi
130 MPa18.9 ksi

Fracture Toughness (K_IC)

40 MPa·√m36.4 ksi·√in
45 MPa·√m41 ksi·√in

Hardness, Brinell

65 HB
110 HB

Hardness, Vickers

70 HV
118 HV

Same in both: Elastic (Young's) Modulus 78 GPa11.3 Msi · Shear Modulus 29.5 GPa4.3 Msi · Bulk Modulus 76 GPa11 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.63 g/cm³0.1 lb/in³ · Melting Point (Solidus) 545°C1,013 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

120 W/m·K69.3 BTU/hr·ft·°F
82 W/m·K47.4 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.3 µm/m·K12.4 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Max Service Temperature (continuous) 120°C248 °F · Min Service Temperature -253°C-423 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

33 % IACS
21 % IACS

Electrical Resistivity

5.2×10⁻⁸ Ω·m2.05 µΩ·in
8.2×10⁻⁸ Ω·m3.23 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

45 / 100
38 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.72 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
48 / 100

Machinability Rating (AISI 1212 = 100 %)

28%
34%

Weldability

35 / 100
30 / 100

Formability (cold)

75 / 100
60 / 100

Same in both: Castability 25 / 100 · Brazeability / Solderability 15 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 230 MJ/kg98,882 BTU/lb · Embodied Carbon (primary production) 14 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 5%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale2199

2199-O vs 2199-T3 — frequently asked

Is 2199-T3 stronger than 2199-O?

Yes. 2199-T3 has a typical yield strength of 270 MPa (39.2 ksi) against 135 MPa (19.6 ksi) for 2199-O — about 100% more. Tensile strength is 400 MPa (58 ksi) vs 250 MPa (36.3 ksi).

Which condition does FabDigit quote by default, O or T3?

T8E74 is the default 2199 condition in the FabDigit quote flow (neither O nor T3). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 2199-O or 2199-T3?

2199-T3, by a small margin. Both rate fair for machinability — 48/100 against 40/100 for 2199-O; for welding the order is 2199-O first (fair, 35/100) then 2199-T3 (poor, 30/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 2199-O and 2199-T3 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.