FabDigitFabDigit

Aluminum 2025-F vs 2025-O

Aluminum · 2025 temper comparison

2025-F and 2025-O are two conditions of the same aluminum grade, 2025: F (as fabricated) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 2025-F is the stronger of the two: yield strength 140 MPa (20.3 ksi) against 95 MPa (13.8 ksi) for 2025-O, about 47% more; tensile strength follows at 260 MPa (37.7 ksi) vs 205 MPa (29.7 ksi). In exchange, 2025-O is the more ductile: elongation 24% versus 20% for 2025-F, and 2025-F is harder (70 HB vs 55 HB).

2025-FChoose it when strength drives the design.

2025-OChoose it when the part is bent, formed or impact-loaded.

2025-F vs 2025-O: properties

2025-F2025-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

260 MPa37.7 ksi
205 MPa29.7 ksi

Yield Strength (0.2% offset)

140 MPa20.3 ksi
95 MPa13.8 ksi

Elongation at Break

20%
24%

Shear Strength

165 MPa23.9 ksi
130 MPa18.9 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
125 MPa18.1 ksi

Hardness, Brinell

70 HB
55 HB

Hardness, Vickers

74 HV
118 HV

Same in both: Elastic (Young's) Modulus 72 GPa10.4 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.81 g/cm³0.1 lb/in³ · Melting Point (Solidus) 520°C968 °F · Liquidus Temperature 640°C1,184 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

170 W/m·K98.2 BTU/hr·ft·°F
180 W/m·K104 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 875 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.7 µm/m·K12.6 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

45 % IACS
47 % IACS

Electrical Resistivity

3.8×10⁻⁸ Ω·m1.5 µΩ·in
4.3×10⁻⁸ Ω·m1.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

32 / 100
40 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.64 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

105%
150%

Weldability

30 / 100
25 / 100

Formability (cold)

55 / 100
70 / 100

Same in both: Brazeability / Solderability 20 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 10%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale2025

2025-F vs 2025-O — frequently asked

Is 2025-F stronger than 2025-O?

Yes. 2025-F has a typical yield strength of 140 MPa (20.3 ksi) against 95 MPa (13.8 ksi) for 2025-O — about 47% more. Tensile strength is 260 MPa (37.7 ksi) vs 205 MPa (29.7 ksi).

Which condition does FabDigit quote by default, F or O?

T6 is the default 2025 condition in the FabDigit quote flow (neither F nor O). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 2025-F or 2025-O?

2025-F, by a small margin. Both rate fair for machinability — 45/100 against 40/100 for 2025-O; for welding the order is 2025-F first (poor, 30/100) then 2025-O (poor, 25/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 2025-F and 2025-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.