FabDigitFabDigit

Aluminum 1235-H111 vs 1235-H12

Aluminum · 1235 temper comparison

1235-H111 and 1235-H12 are two conditions of the same aluminum grade, 1235: H111 (slightly strain hardened) versus H12 (strain hardened, quarter hard). The chemistry is identical, so every difference below comes from the condition. 1235-H12 is the stronger of the two: yield strength 75 MPa (10.9 ksi) against 45 MPa (6.53 ksi) for 1235-H111, about 67% more; tensile strength follows at 95 MPa (13.8 ksi) vs 85 MPa (12.3 ksi). In exchange, 1235-H111 is the more ductile: elongation 25% versus 12% for 1235-H12, and 1235-H12 is harder (26 HB vs 23 HB). 1235-H111 runs hotter in service (150°C vs 120°C continuous).

1235-H111Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1235-H12Choose it when strength drives the design.

1235-H111 vs 1235-H12: properties

1235-H1111235-H12

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

85 MPa12.3 ksi
95 MPa13.8 ksi

Yield Strength (0.2% offset)

45 MPa6.5 ksi
75 MPa10.9 ksi

Elongation at Break

25%
12%

Shear Strength

55 MPa8 ksi
60 MPa8.7 ksi

Fatigue Strength (Endurance Limit)

35 MPa5.1 ksi
40 MPa5.8 ksi

Hardness, Brinell

23 HB
26 HB

Hardness, Vickers

24 HV
28 HV

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 68 GPa9.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 646°C1,195 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

233 W/m·K135 BTU/hr·ft·°F
231 W/m·K133 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
120°C248 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

62 % IACS
61 % IACS

Electrical Resistivity

2.78×10⁻⁸ Ω·m1.09 µΩ·in
2.83×10⁻⁸ Ω·m1.11 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.79 V · Corrosion Resistance 78 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

26 / 100
29 / 100

Machinability Rating (AISI 1212 = 100 %)

28%
30%

Formability (cold)

95 / 100
88 / 100

Same in both: Weldability 90 / 100 · Castability 35 / 100 · Brazeability / Solderability 75 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1235

1235-H111 vs 1235-H12 — frequently asked

Is 1235-H12 stronger than 1235-H111?

Yes. 1235-H12 has a typical yield strength of 75 MPa (10.9 ksi) against 45 MPa (6.53 ksi) for 1235-H111 — about 67% more. Tensile strength is 95 MPa (13.8 ksi) vs 85 MPa (12.3 ksi).

Which condition does FabDigit quote by default, H111 or H12?

O is the default 1235 condition in the FabDigit quote flow (neither H111 nor H12). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 1235-H111 over 1235-H12?

Pick 1235-H111 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick 1235-H12 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1235-H111 and 1235-H12 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.