FabDigitFabDigit

Aluminum 1100-H112 vs 1100-H14

Aluminum · 1100 temper comparison

1100-H112 and 1100-H14 are two conditions of the same aluminum grade, 1100: H112 (strain hardened from hot working only) versus H14 (strain hardened, half hard). The chemistry is identical, so every difference below comes from the condition. 1100-H14 is the stronger of the two: yield strength 115 MPa (16.7 ksi) against 45 MPa (6.53 ksi) for 1100-H112, about 156% more; tensile strength follows at 125 MPa (18.1 ksi) vs 95 MPa (13.8 ksi). In exchange, 1100-H112 is the more ductile: elongation 25% versus 12% for 1100-H14, and 1100-H14 is harder (32 HB vs 25 HB). 1100-H112 runs hotter in service (200°C vs 120°C continuous). On the shop floor, 1100-H14 machines more easily (fair vs poor).

1100-H112Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1100-H14Choose it when strength drives the design, or when the part is machined in volume.

1100-H112 vs 1100-H14: properties

1100-H1121100-H14

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

95 MPa13.8 ksi
125 MPa18.1 ksi

Yield Strength (0.2% offset)

45 MPa6.5 ksi
115 MPa16.7 ksi

Elongation at Break

25%
12%

Shear Strength

62 MPa9 ksi
75 MPa10.9 ksi

Fatigue Strength (Endurance Limit)

34 MPa4.9 ksi
48 MPa7 ksi

Hardness, Brinell

25 HB
32 HB

Hardness, Vickers

28 HV
35 HV

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 76 GPa11 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 643°C1,189 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

200°C392 °F
120°C248 °F

Same in both: Thermal Conductivity 222 W/m·K128 BTU/hr·ft·°F · Specific Heat Capacity 904 J/kg·K0.22 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -273°C-459 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

59 % IACS
57 % IACS

Electrical Resistivity

2.92×10⁻⁸ Ω·m1.15 µΩ·in
3.02×10⁻⁸ Ω·m1.19 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

80 / 100
78 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

22%
30%

Formability (cold)

95 / 100
85 / 100

Same in both: Weldability 95 / 100 · Castability 30 / 100 · Brazeability / Solderability 92 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 210 MJ/kg90,284 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1100

1100-H112 vs 1100-H14 — frequently asked

Is 1100-H14 stronger than 1100-H112?

Yes. 1100-H14 has a typical yield strength of 115 MPa (16.7 ksi) against 45 MPa (6.53 ksi) for 1100-H112 — about 156% more. Tensile strength is 125 MPa (18.1 ksi) vs 95 MPa (13.8 ksi).

Which condition does FabDigit quote by default, H112 or H14?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 1100-H112 or 1100-H14?

1100-H14. Its machinability rates fair (38/100) against poor (28/100) for 1100-H112.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1100-H112 and 1100-H14 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.