FabDigitFabDigit

Aluminum 1080A-H14 vs 1080A-O

Aluminum · 1080A temper comparison

1080A-H14 and 1080A-O are two conditions of the same aluminum grade, 1080A: H14 (strain hardened, half hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 1080A-H14 is the stronger of the two: yield strength 85 MPa (12.3 ksi) against 20 MPa (2.9 ksi) for 1080A-O, about 4.3 times as much; tensile strength follows at 100 MPa (14.5 ksi) vs 70 MPa (10.2 ksi). In exchange, 1080A-O is the more ductile: elongation 40% versus 8% for 1080A-H14, and 1080A-H14 is harder (27 HB vs 19 HB). 1080A-O runs hotter in service (200°C vs 110°C continuous).

1080A-H14Choose it when strength drives the design.

1080A-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1080A-H14 vs 1080A-O: properties

1080A-H141080A-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

100 MPa14.5 ksi
70 MPa10.2 ksi

Yield Strength (0.2% offset)

85 MPa12.3 ksi
20 MPa2.9 ksi

Elongation at Break

8%
40%

Shear Strength

62 MPa9 ksi
50 MPa7.3 ksi

Fatigue Strength (Endurance Limit)

34 MPa4.9 ksi
22 MPa3.2 ksi

Hardness, Brinell

27 HB
19 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33 · Hardness, Vickers 21 HV

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 646°C1,195 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

230 W/m·K133 BTU/hr·ft·°F
231 W/m·K133 BTU/hr·ft·°F

Max Service Temperature (continuous)

110°C230 °F
200°C392 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.5 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

61.5 % IACS
62 % IACS

Same in both: Electrical Resistivity 2.78×10⁻⁸ Ω·m1.09 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.84 V · Corrosion Resistance 80 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
20 / 100

Formability (cold)

78 / 100
100 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 92 / 100 · Castability 35 / 100 · Brazeability / Solderability 60 / 100 · Polishability 95 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 215 MJ/kg92,433 BTU/lb · Embodied Carbon (primary production) 13 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 2%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1080A

1080A-H14 vs 1080A-O — frequently asked

Is 1080A-H14 stronger than 1080A-O?

Yes. 1080A-H14 has a typical yield strength of 85 MPa (12.3 ksi) against 20 MPa (2.9 ksi) for 1080A-O — about 4.3 times as much. Tensile strength is 100 MPa (14.5 ksi) vs 70 MPa (10.2 ksi).

Which condition does FabDigit quote by default, H14 or O?

O is the default 1080A condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1080A-H14 or 1080A-O?

1080A-H14, by a small margin. Both rate poor for machinability — 28/100 against 20/100 for 1080A-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1080A-H14 and 1080A-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.