FabDigitFabDigit

Titanium Ti-6242-STA vs Ti-6242 Stress Relieved

Titanium · Ti-6242 temper comparison

Ti-6242-STA and Ti-6242 Stress Relieved are two conditions of the same titanium grade, Ti-6242: STA (solution treated and aged) versus Stress Relieved. The chemistry is identical, so every difference below comes from the condition. Ti-6242-STA is the stronger of the two: yield strength 1,000 MPa (145 ksi) against 940 MPa (136 ksi) for Ti-6242 Stress Relieved, about 6% more; tensile strength follows at 1,100 MPa (160 ksi) vs 1,010 MPa (146 ksi). In exchange, Ti-6242 Stress Relieved is the more ductile: elongation 14% versus 12% for Ti-6242-STA, and Ti-6242-STA is harder (35 HRC vs 33 HRC).

Ti-6242-STAChoose it when strength drives the design.

Ti-6242 Stress RelievedChoose it when the part is bent, formed or impact-loaded.

Ti-6242-STA vs Ti-6242 Stress Relieved: properties

Ti-6242-STATi-6242 Stress Relieved

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

1,100 MPa160 ksi
1,010 MPa146 ksi

Yield Strength (0.2% offset)

1,000 MPa145 ksi
940 MPa136 ksi

Elongation at Break

12%
14%

Reduction in Area

25%
31%

Compressive Strength

965 MPa140 ksi
975 MPa141 ksi

Shear Strength

640 MPa92.8 ksi
645 MPa93.5 ksi

Fatigue Strength (Endurance Limit)

560 MPa81.2 ksi
505 MPa73.2 ksi

Fracture Toughness (K_IC)

50 MPa·√m45.5 ksi·√in
60 MPa·√m54.6 ksi·√in

Hardness, Brinell

310 HB
311 HB

Hardness, Rockwell C

35 HRC
33 HRC

Hardness, Vickers

350 HV
325 HV

Same in both: Elastic (Young's) Modulus 114 GPa16.5 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 106 GPa15.4 Msi · Poisson's Ratio 0.32 · Charpy V-Notch Impact (RT) 20 J14.8 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 4.54 g/cm³0.16 lb/in³ · Melting Point (Solidus) 1,650°C3,002 °F · Liquidus Temperature 1,705°C3,101 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

510°C950 °F
540°C1,004 °F

Same in both: Thermal Conductivity 7 W/m·K4 BTU/hr·ft·°F · Specific Heat Capacity 460 J/kg·K0.11 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 7.7 µm/m·K4.3 µin/in·°F · Latent Heat of Fusion 365 J/g157 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.1 % IACS · Electrical Resistivity 1.6×10⁻⁶ Ω·m63 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.08 V · Corrosion Resistance 85 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

15 / 100
18 / 100

Weldability

60 / 100
62 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Formability (cold) 25 / 100 · Castability 30 / 100 · Brazeability / Solderability 35 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 650 MJ/kg279,450 BTU/lb · Embodied Carbon (primary production) 44 kg CO₂/kg · Embodied Water 520 L/kg62.3 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every titanium grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0004.555.5Density (g/cm³)Yield strength (MPa) — log scaleTi-6242

Ti-6242-STA vs Ti-6242 Stress Relieved — frequently asked

Is Ti-6242-STA stronger than Ti-6242 Stress Relieved?

Yes. Ti-6242-STA has a typical yield strength of 1,000 MPa (145 ksi) against 940 MPa (136 ksi) for Ti-6242 Stress Relieved — about 6% more. Tensile strength is 1,100 MPa (160 ksi) vs 1,010 MPa (146 ksi).

Which condition does FabDigit quote by default, STA or Stress Relieved?

O is the default Ti-6242 condition in the FabDigit quote flow (neither STA nor Stress Relieved). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose Ti-6242-STA over Ti-6242 Stress Relieved?

Pick Ti-6242-STA when strength drives the design. Pick Ti-6242 Stress Relieved when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Ti-6242-STA and Ti-6242 Stress Relieved side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.