TA15-AW and TA15-M are two conditions of the same titanium grade, TA15: AW (as-welded deposit) versus M (thermomechanically controlled processed). The chemistry is identical, so every difference below comes from the condition. Both yield at about 870 MPa — the mechanical properties are the same, and the difference is in how the stock is processed and what it is certified to (as-welded deposit versus thermomechanically controlled processed). TA15-M is the more ductile: elongation 12% versus 7% for TA15-AW, and TA15-AW is harder (35 HRC vs 33 HRC). TA15-M runs hotter in service (500°C vs 450°C continuous).

TA15-MChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

TA15-AW vs TA15-M: properties

TA15-AWTA15-M

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

114 GPa16.5 Msi
115 GPa16.7 Msi

Tensile Strength (Ultimate)

950 MPa138 ksi
990 MPa144 ksi

Yield Strength (0.2% offset)

870 MPa126 ksi
900 MPa131 ksi

Elongation at Break

7%
12%

Reduction in Area

20%
35%

Compressive Strength

960 MPa139 ksi
1,000 MPa145 ksi

Shear Strength

595 MPa86.3 ksi
620 MPa89.9 ksi

Fatigue Strength (Endurance Limit)

380 MPa55.1 ksi
480 MPa69.6 ksi

Fracture Toughness (K_IC)

62 MPa·√m56.4 ksi·√in
72 MPa·√m65.5 ksi·√in

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
32 J23.6 ft·lbf

Hardness, Brinell

335 HB
320 HB

Hardness, Rockwell C

35 HRC
33 HRC

Hardness, Vickers

350 HV
335 HV

Same in both: Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 108 GPa15.7 Msi · Poisson's Ratio 0.32

Physical

Density and transition temperatures.

Same in both: Density 4.46 g/cm³0.16 lb/in³ · Melting Point (Solidus) 1,600°C2,912 °F · Liquidus Temperature 1,680°C3,056 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

450°C842 °F
500°C932 °F

Same in both: Thermal Conductivity 7.5 W/m·K4.3 BTU/hr·ft·°F · Specific Heat Capacity 540 J/kg·K0.13 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 8.6 µm/m·K4.8 µin/in·°F · Latent Heat of Fusion 365 J/g157 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 1.1 % IACS · Electrical Resistivity 1.6×10⁻⁶ Ω·m63 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

85 / 100
88 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

16 / 100
18 / 100

Machinability Rating (AISI 1212 = 100 %)

18%
20%

Formability (cold)

18 / 100
32 / 100

Same in both: Weldability 80 / 100 · Brazeability / Solderability 45 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 650 MJ/kg279,450 BTU/lb · Embodied Carbon (primary production) 42 kg CO₂/kg · Embodied Water 500 L/kg59.9 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every titanium grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0004.555.5Density (g/cm³)Yield strength (MPa) — log scaleTA15

TA15-AW vs TA15-M — frequently asked

What is the difference between TA15-AW and TA15-M?

TA15-AW and TA15-M are two conditions of the same titanium grade, TA15: AW (as-welded deposit) versus M (thermomechanically controlled processed). The chemistry is identical, so every difference below comes from the condition. Both yield at about 870 MPa — the mechanical properties are the same, and the difference is in how the stock is processed and what it is certified to (as-welded deposit versus thermomechanically controlled processed).

Which condition does FabDigit quote by default, AW or M?

M is the default TA15 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose TA15-AW over TA15-M?

Pick TA15-M when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in TA15-AW and TA15-M side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.