FabDigitFabDigit

Titanium C-4-ANN vs C-4-F

Titanium · C-4 temper comparison

C-4-ANN and C-4-F are two conditions of the same titanium grade, C-4: ANN (annealed) versus F (as fabricated). The chemistry is identical, so every difference below comes from the condition. C-4-F is the stronger of the two: yield strength 530 MPa (76.9 ksi) against 500 MPa (72.5 ksi) for C-4-ANN, about 6% more. In exchange, C-4-ANN is the more ductile: elongation 15% versus 12% for C-4-F, and C-4-F is harder (265 HB vs 250 HB).

C-4-ANNChoose it when the part is bent, formed or impact-loaded.

C-4-FChoose it when strength drives the design.

C-4-ANN vs C-4-F: properties

C-4-ANNC-4-F

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

590 MPa85.6 ksi
620 MPa89.9 ksi

Yield Strength (0.2% offset)

500 MPa72.5 ksi
530 MPa76.9 ksi

Elongation at Break

15%
12%

Reduction in Area

25%
20%

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
240 MPa34.8 ksi

Fracture Toughness (K_IC)

66 MPa·√m60.1 ksi·√in
60 MPa·√m54.6 ksi·√in

Charpy V-Notch Impact (RT)

18 J13.3 ft·lbf
14 J10.3 ft·lbf

Hardness, Brinell

250 HB
265 HB

Hardness, Rockwell C

24 HRC
26 HRC

Hardness, Vickers

262 HV
280 HV

Same in both: Elastic (Young's) Modulus 104 GPa15.1 Msi · Shear Modulus 45 GPa6.5 Msi · Bulk Modulus 110 GPa16 Msi · Poisson's Ratio 0.34 · Compressive Strength 560 MPa81.2 ksi · Shear Strength 430 MPa62.4 ksi

Physical

Density and transition temperatures.

Same in both: Density 4.51 g/cm³0.16 lb/in³ · Melting Point (Solidus) 1,660°C3,020 °F · Liquidus Temperature 1,670°C3,038 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 17.2 W/m·K9.9 BTU/hr·ft·°F · Specific Heat Capacity 544 J/kg·K0.13 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 8.6 µm/m·K4.8 µin/in·°F · Latent Heat of Fusion 320 J/g138 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 2.9 % IACS · Electrical Resistivity 6×10⁻⁷ Ω·m23.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.1 V · Corrosion Resistance 92 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

34 / 100
30 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 35% · Weldability 85 / 100 · Formability (cold) 20 / 100 · Castability 60 / 100 · Brazeability / Solderability 40 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 650 MJ/kg279,450 BTU/lb · Embodied Carbon (primary production) 39 kg CO₂/kg · Embodied Water 900 L/kg108 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every titanium grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

3005007001,0004.555.5Density (g/cm³)Yield strength (MPa) — log scaleC-4

C-4-ANN vs C-4-F — frequently asked

Is C-4-F stronger than C-4-ANN?

Yes. C-4-F has a typical yield strength of 530 MPa (76.9 ksi) against 500 MPa (72.5 ksi) for C-4-ANN — about 6% more. Tensile strength is 620 MPa (89.9 ksi) vs 590 MPa (85.6 ksi).

Which condition does FabDigit quote by default, ANN or F?

F is the default C-4 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C-4-ANN over C-4-F?

Pick C-4-ANN when the part is bent, formed or impact-loaded. Pick C-4-F when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C-4-ANN and C-4-F side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.